Herunterladen Inhalt Inhalt Diese Seite drucken

HEYLO K 220 Bedienungsanleitung Seite 34

Mobile warmlufterzeuger; k (öl) serie
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mobile warm-air heaters
Type K 220
Problem
Burner does not switch
off
Room thermostat
switches burner off
before the desired room
temperature has been
reached
Ventilator does not start
up
If the device is being supplied with power through the mains cable, work on the
electrical unit can only be carried out by specialist electricians and/or a person
trained in this area in accordance with VBG 4.
Please only get repair work to the electrical, gas and oil connections for fan-assisted air heaters
done by HEYLO service partners.
Placing the device out of operation and disposal
The device is designed for long term operation.
If it is to be disposed of, this must be done in accordance with the current relevant legal
regulations in an environment friendly manner.
Any more questions? We would be glad to help!
Your HEYLO customer service:
Tel.
+49 (0) 42 02 – 97 55 15
Fax
+49 (0) 42 02 – 97 55 97
Email service@heylo.de
Possible cause
Room thermostat has been fitted in
an inappropriate place.
Defective room thermostat
The room thermostat has been
fitted to a place where it comes into
contact with hot air or rays of heat,
e.g. from the sun, machines, hot
water or steam pipes.
Temperature regulator 3S2.1 (see
wiring diagram) is not functioning
No power supply
34
Solution
Fit the room thermostat at another
place. It is important, for proper
controlling, that the room thermostat if
fitted in the room to be heated, should
be fitted in such a way that no flow of
cold air from windows, doors etc.
comes into contact with it. If
appropriate, move the room thermostat
to another place.
Examine the room thermostat (can
only be done by an expert), change it
in emergency cases.
Move the thermostat to another place
Check,
whether
the
regulator
3S2.1
is
functioning,
necessary it has to be exchanged.
Check the terminal strip X2 with a
voltage tester (see wiring diagram) to
see whether the ventilator drive is
being supplied with electricity.
Terminal 1,2,3 (see wiring diagram).
temperature
if
EN

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1101684

Inhaltsverzeichnis