Pego ECP202BASE Kurzanleitung Seite 5

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
AU1
Auxiliary/alarm relay 1 control
AU2
Auxiliary/alarm relay 2 control
StA
Temperature setting for auxiliary relay
Correction factor for the SET button
during night operation (energy saving)
(with In1 or In2 = 8 or -8).
nSC
During night operation the control set is:
Set Control = Set + nSC
In night mode decimal point flashes.
In1
INP-1 input setting
In2
INP-2 input setting
bEE
Buzzer enable
mOd
Thermostat functioning mode
Password type of protection
P1
(active when PA is not equal 0)
Rev. 01-21
-6 (NC) = relay de-energised during stand-by.
-5 (NC) = Contact for casing element control (AUX
relay closed with compressor output inactive).
-4 (NC) = pump down function (NC, see CHAP
5.16).
-3 (NC) = automatic auxiliary relay managed by StA
temp. setting with 2°C differential (NC).
-2 (NC) = manual auxiliary relay controlled via AUX
key (NC).
-1 (NC) = alarm relay (NC).
0 = relay deactivated.
1 (NO) = alarm relay (NO).
2 (NO) =manual auxiliary relay controlled via AUX
key (NO).
3 (NO) = automatic auxiliary relay managed by StA
temp. setting with 2°C differential (NO).
4 (NO) = pump down function (NO, see CHAP
5.16).
5 (NO) = free voltage contact for condensing unit
(AUX relay and compressor relay in parallel).
6 (NO) = relay excited during stand-by.
- Same AU1 values legend -
8 = Night mode digital input (energy saving, N.O.)
7 = Stop defrosting remotely (N.O.) (reads rising
edge of impulse)
6 = Start defrosting remotely (N.O.) (reads rising
edge of impulse)
5 = Stand-by remotely (N.O.) (In order to indicate
Stand-By mode, the display shows 'In5'
alternating with the current view)
4 = Pump-down pressure switch (N.O.)
3 = Man-in-room alarm (N.O.)
2 = Compressor protection (N.O.)
1 = Door switch (N.O.)
0 = disabled
-1 = Door switch (N.C.)
-2 = Compressor protection (N.C.)
-3 = Man-in-room alarm (N.C.)
-4 = Pump-down pressure switch (N.C.)
-5 = Stand-by remotely (N.C.) (In order to indicate
Stand-By mode, the display shows 'In5'
alternating with the current view)
-6 = Start defrosting remotely (N.C.) (reads falling
edge of impulse)
-7 = Stop defrosting remotely (N.C.) (reads falling
edge of impulse)
-8 = Night mode digital input (energy saving, N.C.)
- Same In1 values legend -
0 = disabled
1 = enabled
0 = Cold function
1 = Hot function (in this mode defrosting
and fan disable Fst are excluded)
0 = only display set point
1 = display set point, AUX, light access
2 = access in programming not permitted
3 = access in second level programming
not permitted
ECP202 BASE – Parameters Abstract
-45 ÷ +99°C
-20,0 ÷ +20,0 °C
-1
5
0 °C
0,0 °C
2
1
1
0
3
Pag. 5