TECHNICAL DATA
Rated input ..............................................................................
Output ......................................................................................
No-load speed, 1st gear ..........................................................
No-load speed, 2nd gear .........................................................
No-load speed, 3rd gear ..........................................................
No-load speed, 4th gear ..........................................................
Speed under load max., 1st gear ............................................
Speed under load max., 2nd gear ...........................................
Speed under load max., 3rd gear ............................................
Speed under load max., 4th gear ............................................
Drilling capacity in steel ...........................................................
Drilling capacity in Aluminium ..................................................
Drilling capacity in soft- wood ..................................................
Chuck reception morse taper ..................................................
Chuck neck diameter ...............................................................
Weight according EPTA-Procedure 01/2003 ...........................
Noise Information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (K = 3 dB(A)) .......................................
Sound power level (K = 3 dB(A)) ............................................
Wear ear protectors!
Vibration Information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
:..................................................
h
Uncertainty K = ....................................................................
Measured values determined according to EN 60 745.
The data stated above apply for models with 230 - 240 V.In
case of deviating mains voltage, the data stated on the rating
plate are applicable.
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions
may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Wear ear protectors. Exposure to noise can cause hearing
loss.
Use auxiliary handles supplied with the tool. Loss of
control can cause personal injury.Appliances used at many
different locations including open air must be connected via
a current surge preventing switch.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory
may contact hidden wiring or its own cord. Contact with
a "live" wire will also make exposed metal parts of the power
tool "live" and shock the operator.
Appliances used at many different locations including open
air should be connected via a residual current device of
30 mA or less.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes
and apron.
12
ENGLISH
All manuals and user guides at all-guides.com
.......................1050 W
.........................525 W
.........................220 min
-1
.........................250 min
-1
.........................350 min
-1
.........................420 min
-1
......................... 115 min
-1
.........................160 min
-1
.........................190 min
-1
.........................260 min
-1
...........................32 mm
...........................64 mm
...........................52 mm
...................... MK 3
...........................57 mm
..........................7,5 kg
...........................85 dB (A)
...........................96 dB (A)
...........................12 m/s
2
..........................2,9 m/s
2
Sawdust and splinters must not be removed while the
machine is running.
Always disconnect the plug from the socket before carrying
out any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The drill can be used for drilling in wood, metal and plastics.
Do not use this product in any other way as stated for
normal use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also
possible to connect to sockets without an earthing contact
as the design conforms to safety class II.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is
in conformity with the following standards or standardized
documents.
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2006 + A1:2009 + A2:2009
EN 61000-3-3:2008
in accordance with the regulations
2011/65/EU (RoHs)
2006/42/EC
2004/108/EC
Winnenden, 2012-09-12
Rainer Kumpf
Director Product Development
Authorized to compile the technical file
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have
not been described, please contact one of our Milwaukee
service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered.
Please state the ten-digit No. as well as the machine type
printed on the label and order the drawing at your local
service agents or directly at: Milwaukee Electric Tool,
Max-Eyth-Straße 10, D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Always disconnect the plug from the socket
before carrying out any work on the
machine.
Accessory - Not included in standard
equipment, available as an accessory.
Do not dispose of electric tools together
with household waste material! In
observance of European Directive 2002/96/
EC on waste electrical and electronic
equipment and its implementation in
accordance with national law, electric tools
that have reached the end of their life must
be collected separately and returned to an
environmentally compatible recycling
facility.
Class II construction, tool in which
protection against electric shock does not
rely on basic insulation only, but in which
additional safety precautions, such as
double insulation or reinforced insulation,
are provided.