7. Dismantling and Re-Installation
3.
4.
5.
Retain the clamping pressure.
Manually loosen the safety nut.
WARNING
The nut must always remain
held with at least two turns of
its thread.
Release pressure and connect
the pump to the connection
"Entspannen" (Loosen).
1
2
Increasing the oil pressure
(max. 450 bar!) will initiate the
release of the connection.
WARNING
As soon as the outer ring
starts moving towards the
nut, reduce the oil pressure
immediately to a maximum of
150 bar.