Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance Instruction - Suntec Wellness KLIMATRONIC DryFix 20 Design Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für KLIMATRONIC DryFix 20 Design:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
-
Make sure that the hose is securely connected to prevent leakage of water.

MAINTENANCE INSTRUCTION

1. Please always unplug the unit before cleaning.
2. Please note that only the dust filter may be cleaned.
3. Remove the front cover and carefully remove the dust filter.
4. If the filter is only slightly dusty, you can quickly and easily clean it with a vacuum cleaner.
5. If you are using an activated carbon filter, carefully remove the dirt and then put the filter back
into the appliance together with the dust filter.
6. Once the filter is cleaned, use the reset button to reset the filter change indicator.
7. Rinse the filter under running water (max. 40 ° C) and dry it with a soft cloth.
8. Clean the appliance with a damp cloth and then wipe with a dry cloth.
9. Do not use chemical solvents (such as benzene, alcohol) or hot water.
10. If the unit will not be used over longer period, please turn the power off, unplug the power cord
and take the unit in a dry, cool and safe place
TROUBLESHOOTING
Problem
Hot air comes from the air outlet
The unit does not work.
The device does not
dehumidify.
Cause
-----------
Is the unit plugged in?
Check the ambient
temperature.
Does the "tank full" indicator
(water tank is full or misplaced)
light up?
Is the air inlet or outlet blocked?
Is the ambient temperature or
relative humidity too low?
Solution
The dehumidifier has no cooling
function; the air comes out of
the condenser. This is not a
defect.
Plug in the unit.
The temperature should be
between 5 - 35°C.
Empty the water tank and set it
to the correct position again.
Check the air inlet and outlet
and remove any obstructions.
Please check the settings on
the unit. If the set humidity is
below the ambient humidity and
/ or 20%, the unit stops
dehumidifying.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis