3 - DESCRIPTION AND SIZE

3.1 DESCRIPTION (Fig. 1)
The main elements of the stove are shown below :
(1) Front
(2) Air intake control
(3) Strip
(4) Loading door
(5) Handle
A secondary air inlet is integrated in the upper section of the door window to maintain it clean and
ensure improved wood combustion.
The air setting lever, located at the back of the appliance, allows you to choose a fire pace.
Stove net weight :
3.2 SIZE (Fig. 2)
Outer dimensions (mm)
C07751

3.3 - VENTILATION OF THE AREA IN WHICH THE APPLIANCE IS TO BE INSTALLED

The appliance needs air in addition to the air required by the statutory air change rate. This is obligatory when the
dwelling includes mechanical ventilation.
The air intake should give directly to the outside or should be located in an area ventilated to the outside ; it
should also be protected by a grille.
The air outlet should be as near as possible to the stove. The user should be able to close it off when it comes
out directly into the room. While the appliance is being used, make sure that it is free of any obstructions.
The air intake section should be at least equal to one-quarter of the section of the smoke flue with a minimum of :
2
- 50 cm
for use with the door closed only
It may be necessary to stop the extractor of the mechanical ventilation so as to avoid smoke coming back into the
room when the door is opened.

4 - STOVE OPERATING CONDITIONS

4.1 FIRST LIGHTING

- Once the chimney is implemented and the stove set, observe the drying time of the materials used for
the construction (2 to 3 weeks).
- Do not connect the stove to a pipe linked to several appliances.
- After first lighting (see paragraph 4.4.1), make a moderate fire for the first hours by limiting the stove's
load (a 15cm diameter log) (air damper half-open).
. Progressive heating of all the elements in the chimney and normal stove expansion.
- During the first hours of use, the stove may produce a smell of paint : ventilate the room to limit its
effects.
(6) Ashtray
(7) Ashtray handle
(8) Panel
(9) Deflector
(10) the basket
C07751 Stove approx. 54 kg
Width
580
Height
625