suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: On the rear panel, there are 2 holes for the installation.
Step 2: Hold the rear panel onto the location where the device is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the rear panel in the desired position and tighten it.
5.3 Connections
5.3.1 Connection with the mains
The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power supply cable and a power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
5.3.2 Outputs
Output is via 6 safety sockets.
Connect your loads via the output-sockets. The maximum load per channel is 3,680 W (resistive). Please
note that the maximum current must never be exceeded.
Before taking into operation for the first time, the installation has to be approved by an expert!

6. CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
DANGER TO LIFE!
International
L
N
DANGER TO LIFE!
14/15
30240410_V_1_0.DOC