An electric animal fence shall not be supplied from two separate energizers or from independent fence circuits
of the same energizer.
For any two separate electric animal fences, each supplied from a separate energizer independently timed, the
distance between the wires of the two electric animal fences shall be at least 2.5m. If this gap is to be closed,
this shall be effected by means of electrically non-conductive material or an isolated metal barrier.
Barbed wire or razor wire shall not be electrified by an energizer.
A non-electrified fence incorporating barbed wire or razor wire may be used to support one or more off-set
electrified wires of an electric animal fence. The supporting devices for the electrified wires shall be constructed
so as to ensure that these wires are positioned at a minimum distance of 150 mm from the vertical plane of the
non-electrified wires. The barbed wire and razor wire shall be earthed at regular intervals.
Follow the energizer manufacturer's recommendations regarding earthing.
Do not install an earth (ground) system for your electric fence within 10 m (33 ft) of any power,
telecommunications or other system.
Use high voltage lead-out cable in buildings to effectively insulate from the earthed structural parts of the
building and where soil could corrode exposed galvanized wire. Do not use household electrical cable.
Connecting leads that are run underground shall be run in conduit of insulating material or else insulated high
voltage lead-out cable shall be used. Care must be taken to avoid damage to the connecting leads due to the
effects of animal hooves or tractor wheels sinking into the ground.
Connecting leads shall not be installed in the same conduit as the mains supply wiring, communication cables
or data cables.
Connecting leads and electric animal fence wires shall not cross above overhead power or communication lines.
Crossings with overhead power lines shall be avoided wherever possible. If such a crossing cannot be avoided it
shall be made underneath the power line and as nearly as possible at right angles to it.
If connecting leads and electric animal fence wires are installed near an overhead power line, the clearances
shall not be less than those shown in the table below.
Minimum clearances from power lines for electric animal fences
Less than or equal to 1 000
Greater than 1 000 and less than or equal to 33 000
Greater than 33 000
If connecting leads and electric animal fence wires are installed near an overhead power line, their height
above the ground shall not exceed 3 m.
This height applies either side of the orthogonal projection of the outermost conductors of the power line on
the ground surface, for a distance of:
- 2 m for power lines operating at a nominal voltage not exceeding 1 000 V;
- 15 m for power lines operating at a nominal voltage exceeding 1 000 V.
Electric animal fences intended for deterring birds, household pet containment or training animals such as cows
need only be supplied from low output energizers to obtain satisfactory and safe performance.
In electric animal fences intended for deterring birds from roosting on buildings, no electric fence wire shall be
connected to an earth stake. A warning sign shall be fitted to every point where persons may gain ready access
to the conductors.
4
Power line Voltage V
3E4097 Gallagher S400 Solar Energizer User Manual
Clearance m
3
4
8