Herunterladen Inhalt Inhalt Diese Seite drucken

Sauter EGQ212F931 Bedienungs- Und Montageanleitung

Multifunktionaler kanalfühler mit messumformer für temperatur und co2-gehalt, selbstkalibrierend, inkl. montageflansch, mit aktivem ausgang

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

D G F I
6000-3750-0000-1XXSI 37500-2021-SI V107 05 ⁄ 07 ⁄ 2021
EGQ212F931
D
Bedienungs- und Montageanleitung
Multifunktionaler Kanalfühler mit Messumformer
für Temperatur und CO2 - Gehalt, selbstkalibrierend,
inkl. Montageflansch,
mit aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Multifunctional duct sensors with measuring transducers
for temperature and CO2 content, self-calibrating,
incl. mounting flange,
with active output
F
Notice d'instruction
Sonde (transmetteur) de gaine multifonctionnelle
pour la température et la teneur en CO2, auto-calibrant,
avec compris bride de montage,
avec sortie active
I
Istruzioni per l'uso e per il montaggio
Sonda multifunzionale per canale con trasmettitore di misura
per temperatura e livello di CO2, calibrazione automatica,
inclusa flangia di montaggio,
con uscita attiva
Sauter Italia S.p.A.
Via Dei Lavoratori, 131
20092, Cinisello Balsamo
Italia
Tel. +39 022 80481
Fax +39 022 8048280
info@it.sauter-bc.com
www.sauteritalia.it
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für Sauter EGQ212F931

  • Seite 1 Istruzioni per l'uso e per il montaggio Sonda multifunzionale per canale con trasmettitore di misura per temperatura e livello di CO2, calibrazione automatica, inclusa flangia di montaggio, con uscita attiva Sauter Italia S.p.A. Via Dei Lavoratori, 131 20092, Cinisello Balsamo Italia Tel. +39 022 80481...
  • Seite 2 D G F I EGQ212F931 Maßzeichnung EGQ212F931 Dimensional drawing Plan coté Disegno quotato M16x1.5 ø32.3 ø 20 M16x1.5 Montageflansch aus Kunststoff Mounting flange, plastic Bride de montage en matière plastique Flangia di montaggio in plastica...
  • Seite 3 D G F I EGQ212F931 EGQ212F931 Einbauschema Mounting diagram Schéma de montage Schema di montaggio...
  • Seite 4: Technische Daten

    EGQ212F931 Rev. 2021 - V33 Wartungsfreier Kanalfühler mit aktivem Ausgang, automatischer Kalibrierung, im schlagfesten Kunststoffgehäuse mit Schnell verschluss schrauben, zur Ermittlung des CO2-Gehalts der Luft (0...2000 ppm / 0...5000 ppm) und der Temperatur (–35...+80 °C). Der Messumformer wandelt die Mess- größen in ein Normsignal von 0 -10 V.
  • Seite 5 EGQ212F931 Rev. 2021 - V33 ACHTUNG !  Die minimale CO2 - Konzentration von Außenluft beträgt in begrünten, industrie armen Gegenden ca. 350 ppm (Ausgangs spannung = 1,75 V bei MB = 0...2000 ppm bzw. 0,7 V bei MB = 0...5000 ppm). Der Gas austausch im Sensorelement erfolgt durch Diffusion. Je nach Konzentrationsänderung und Strömungs geschwindigkeit der Luft in Sensor umgebung kann die Reaktion des Gerätes auf die Konzentrationsänderung verzögert auftreten.
  • Seite 6: Versorgungsspannung

    EGQ212F931 Rev. 2021 - V33 Schaltbild Einzelbetrieb Schaltbild Parallelbetrieb Schaltung Schaltung Schaltung Versorgung mit AC 24V~ Versorgung mit DC 15-36V = GND AC 24V~ DC 15-36V = GND VERSORGUNGSSPANNUNG: Werden mehrere Geräte von einer 24 V AC - Spannung versorgt, ist darauf zu achten, dass alle „positiven“...
  • Seite 7: D Wichtige Hinweise

    – Schwingungen, Vibrationen, Stöße sind zu vermeiden (< 0,5 g) Achtung! Berücksichtigen Sie in jedem Fall die mechanischen und thermischen Belastungsgrenzen der Schutzrohre nach DIN 43763 bzw. nach speziellen Sauter-Standards! Irrtümer und technische Änderungen vorbehalten. Alle Angaben entsprechen unserem Kenntnisstand bei Veröffentlichung. Sie dienen nur zur Information über unsere Produkte und deren Anwendungsmöglichkeiten, bieten jedoch keine Gewähr für bestimmte Produkteigenschaften.
  • Seite 8: Technical Data

    EGQ212F931 Rev. 2021 - V33 Maintenance-free duct sensor with active output, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, for deter- mining the CO2 content of the air (0...2000 ppm/0...5000 ppm) and the temperature (–35...+80 °C). The measuring transducer converts the meas- ured values into a standard signal of 0 -10 V.
  • Seite 9 EGQ212F931 Rev. 2021 - V33 ATTENTION !  The minimum CO2 concentration of outside air in leafy, hardly industrialised areas is approx. 350 ppm (output voltage = 1.75 V with MR = 0...2000 ppm or 0.7 V with MR = 0...5000 ppm). The gas inter-exchange in the sensor element happens by diffusion. Depending on the changes to the concentra- tion and the flow velocity of the air surrounding the sensor, the reaction of the device to the change of concentration may take place with a delay.
  • Seite 10: Supply Voltage

    EGQ212F931 Rev. 2021 - V33 Connecting scheme Individual operation Connecting scheme Parallel operation Circuitry Circuitry Circuitry Power supply AC 24V~ Power supply DC 15-36V = GND AC 24V~ DC 15-36V = GND When several devices are supplied by one 24 V AC voltage supply, it is to SUPPLY VOLTAGE : be ensured that all ”positive“...
  • Seite 11 Attention! In any case, please observe the mechanical and thermal load limits of the protective tubes according to DIN 43763 or according to specific Sauter- standards! Subject to errors and technical changes. All statements and data herein represent our best knowledge at date of publication. They are only meant to inform about our products and their application potential, but do not imply any warranty as to certain product characteristics.
  • Seite 12: Caractéristiques Techniques

    EGQ212F931 Rev. 2021 - V33 Sonde de mesure pour montage en gaine sans entretien avec sortie active,calibrage automatique, dans un boîtier plastique résistant aux chocs avec vis de fermeture rapide, pour déterminer la teneur en CO2 dans l’air (0...2000 ppm / 0...5000 ppm) et la température (–35...+80 °C). Le convertis- seur de mesure convertit les grandeurs de mesure en un signal normalisé...
  • Seite 13 EGQ212F931 Rev. 2021 - V33 ATTENTION !  La teneur minimale en CO2 de l'air extérieur dans des régions vertes à faible degré d'industrialisation est de l'ordre 350 ppm (tension de sortie = 1,75 V à MB = 0...2000 ppm, resp. 0,7 V à MB = 0...5000 ppm). L'échange de gazdans l'élément capteur s'effectue par diffusion. En fonction de la variation de la concentration et de la vitesse d'écoulement de l'air dans l'environnement du capteur, la réaction de l'appareil à...
  • Seite 14: Tension D'alimentation

    EGQ212F931 Rev. 2021 - V33 Schéma de raccordement individuel Schéma de raccordement en parallèle Circuitry Circuitry Circuitry Power supply AC 24V~ Power supply DC 15-36V = GND AC 24V~ DC 15-36V = GND TENSION D’ALIMENTATION : Si plusieurs appareils sont alimentés en 24 V ca, il faut veiller à ce que toutes les entrées de tension «...
  • Seite 15 Attention ! Il faut impérativement tenir compte des limites de charge mécanique et thermique des tubes de protection suivant DIN 43763, resp. suivant les standards spécifiques de Sauter ! Sous réserve d'erreurs et de modifications techniques. Toutes les informations correspondent à l'état de nos connaissances au moment de la publication. Elles servent uniquement à...
  • Seite 16: Dati Tecnici

    EGQ212F931 Rev. 2021 - V33 Sonda per canale che non necessita di manutenzione con uscita attiva, calibrazione automatica, in involucro di plastica antiurto con viti a chiusura rapida, per rilevare il livello di CO2 nell’aria (0...2000 ppm / 0...5000 ppm) e la temperatura (–35...+80 °C). Il trasmettitore di misura trasforma le grandezze di misura in un segnale normalizzato di 0 -10 V.
  • Seite 17 EGQ212F931 Rev. 2021 - V33 ATTENZIONE!  La concentrazione minima di CO2 nell’aria esterna delle aree verdi a basso impatto industriale corrisponde a circa 350 ppm (tensione di uscita = 1,75 V a MB = 0...2000 ppm o 0,7 V a MB = 0...5000 ppm). Lo scambio di gas nell’elemeto sensibile avviene per diffusione. A seconda della variazione della con centra zione e della velocità...
  • Seite 18: Tensione Di Alimentazione

    EGQ212F931 Rev. 2021 - V33 Schema di collegamento collegamento singolo Schema di collegamento collegamento in parallelo Circuitry Circuitry Circuitry Power supply AC 24V~ Power supply DC 15-36V = GND AC 24V~ DC 15-36V = GND TENSIONE DI ALIMENTAZIONE: Quando più dispositivi sono alimentati da un'unica alimentazione con ten- sione 24 V AC, è...
  • Seite 19: Avvisi Importanti

    Attenzione! Tenere assolutamente in considerazione i limiti di carico meccanici e termici dei tubi protettivi ai sensi della DIN 43763 o degli standard speciali Sauter! Con riserva di possibili errori e modifiche tecniche. Tutte le informazioni corrispondono al nostro stato di conoscenza al momento della pubblicazione e hanno scopo esclusivamente informativo sui nostri prodotti e sulle relative possibilità...

Inhaltsverzeichnis