Herunterladen Diese Seite drucken

Frequently Asked Question - Comunello SHOWIN MS35SM06H0B00 Bedienungsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27

2. FREQUENTLY ASKED QUESTION

PROBLEMS
1
Motor does not run
Motor runs
2
intermittently
Motor run only one
3
direction
18
CAUSE
Public electricity supply
failure
Repeated operation may
have tripped the motor
overload protector switch
Have the wiring connection
between switch and
motor checked by an
authorized electrician
Too low voltage
The end stop in the other
direction is activated
No power of the other
direction
SOLUTION
Check if the problem also occurs with other actuators
connected to a different switch. Alternatively, check
with a multimeter if voltage is present.
Have it checked by an authorized electrician
Check that the motor is not undersized
Wait 15 min and try again
Replace if necessary
To rate power
Choose the relevant load to the rated torque
Turn the end position adjustment screw in the
direction indicated by the limit switch referred to
the non-functioning direction towards the + sign
Check the wire connection

Werbung

loading