Fault
Splitting column does not drive
out/in
Splitting column has no force
Splitting column stops during
work
Hydraulic lines become very
hot
Electric motor does not start
Electric motor becomes very
hot
Splitting column jerky when
driving in
*
The activities marked with an asterisk shall only be performed by the specialist dealer.
46-113, 46-114 | 11.2018

Faults

If you are not able to repair the wood splitter yourself, contact your
dealer or an authorised repair workshop.
Before you contact your dealer, an authorised repair workshop
i
or the manufacturer, please note the specifications and the
machine number on the type plate. These details are required
for rectifying the problem or ordering spares.
The possible faults, causes and remedies are listed in the table below.
The safety regulations must be observed for all set­up, cleaning,
maintenance and repair work.
Cause
Incorrect turning sense of the
motor (400 V)
Hydraulic oil too low
Hydraulic oil too low
Control valve setting incorrect Adjust*.
Pump worn
Cylinder gasket insert
damaged
Wood too big or knotty
Hydraulic oil too low
Pump damaged
Control valve setting incorrect Adjust*
Mains plug/socket defective
Electrical cable defective
One phase missing
Cable cross section too small
Motor winding damaged
Insufficient grease on the
polyamide guides
Remedy
Check the direction of
rotation and set the phased
turner correctly if necessary
Top up
Top up
Replace*
Replace*
Turn wood
Top up
Replace*
Replace*
Replace
Check
Replace
Replace*
Grease polyamide guides
8 t wood splitter
Faults
63