5 Protection
1) Input reverse polarity protection
If the polarity of the DC input terminal is reversed, the indicator does not light up after powering on, the buzzer
does not sound, and the inverter does not work. The inverter starts to work normally after correcting the
miswiring.
2) Input voltage protection
 When changing the input voltage parameters of the battery, the following rules must be observed:
A. Over voltage limiting voltage (16.2/32.2/64.4V) ≥ overvoltage separation voltage ≥ OverVoltage
reconnect voltage +1V. Over Spannung wieder verbinden Spannung ≥ Niederspannung wieder
verbinden Spannung.
B. Over voltage reconnect voltage ≥ low voltage reconnect voltage.
C. Low voltage reconnection voltage ≥ low voltage separation voltage +1V.
D. Low voltage separation voltage ≥ low voltage limit voltage (10.5/21V).
5. 1 Al a rm message with Offgridtec Remote Meter
Status is displayed as follows when the input voltage protection occurs
Input voltage protection
Over voltage protection
Reconnect after over-the-top
General information
Offgridtec GmbH
Im Gewerbepark 11
84307 Eggenfelden
WEEE-Reg.-Nr. DE37551 136
Contact
Tel: +49 8721 91994-00
Email: info@offgridtec.com
Web: www.offgridtec.com
GFR: Christian & Martin Krannich
Offgridtec PSI-PRO Inverter
Status
The output is off. The blue indicator
flashes quickly.
Buzzer beeps. LCD displays
The blue indicator is ON solid.
The output voltage is normal.
Konto Sparkasse Rottal-Inn
Konto: 10188985
BLZ: 74351430
IBAN: DE69743514300010188985
BIC: BYLADEM1EGF (Eggenfelden)
5 Protection