INSTALLATION

Making the worktop recess
Worktop thickness should be 28 - 40 mm, while its width at least 600 mm. The worktop
must be flat and level. Edge of the worktop near the wall must be sealed to prevent ingress
of water or other liquids.
There should be sufficient spacing around the opening, in particular, at least 50 mm di-
stance to the wall and 60 mm distance to the front edge of worktop.
Worktop must be made of materials, including veneer and adhesives, resistant to a tem-
perature of 100°C. Otherwise, veneer could come off or surface of the worktop become
deformed.
Edge of the opening should be sealed with suitable materials to prevent ingress of water.
Worktop opening must cut to dimensions as shown on figure 1.
Ensure minimum clearance of 80 mm below the hob to allow proper air circulation and
prevent overheating.