Technical data

Digital laser measure
Article number
A)
Measuring range
Measuring range (unfavourable
B)
conditions)
A)
Measuring accuracy
Measuring accuracy (unfavourable
B)
conditions)
Smallest display unit
General
C)
Operating temperature
Permitted charging temperature
range
Storage temperature
Relative air humidity max.
Max. altitude
Pollution degree according to
IEC 61010-1
Laser class
1 609 92A 6UN | (21.09.2021)
GLM 100-25 C
3 601 K72 Y..
0.08–100 m
0.08–60 m
±1.5 mm
±3.0 mm
0.5 mm
–10 °C to +45 °C
–20 °C to +70 °C
90 %
2000 m
D)
2
2
GLM 150-27 C
3 601 K72 Z..
0.08–150 m
0.08–60 m
±1.5 mm
±3.0 mm
0.5 mm
–10 °C to +45 °C
+5 °C to +40 °C
–20 °C to +70 °C
90 %
2000 m
D)
2
2