Lead the end of the hose to the drain.
•
Alternatively, you can use a collecting vessel.
•
Loosen the plug by means of a slotted screwdriver so
far that free rotation of the handle is ensured.
The plug may only be loosened during this phase,
never completely unscrewed!
•
Turn the handle according to the imprinted marking
in the direction of the arrow as far as possible
(approximate four complete turns).
•
The backwashing process has now started
The discharge quantity must be able to be absorbed
by the discharge pipe or the collecting vessel!
Note: During the backwashing process, the pressure
of the heating system must be kept constant. We
recommend the FillingCombi BA 6628 according to
DIN EN 1717.
•
Turn the plug completely out with the magnetic rod.
The metallic sediments are wiped off and rinsed out
during the ongoing backwashing process.
image 5
image 6
The magnetic separator may only be cleaned
during backwashing!
•
Turn the handle according to the imprinted marking
as far as possible (approximate four complete turns).
•
The backwashing process is completed.
image 7
image 8
image 9