Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly And Starting; Replacing The Power Cable; Cleaning, Maintenance And Ordering Of Spare Parts - EINHELL TH-AC 240/50/10 OF Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für TH-AC 240/50/10 OF:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

6. Assembly and starting

Important!
You must fully assemble the appliance before
using it for the fi rst time.
6.1. Fitting the supporting foot (4)
The supplied rubber stopper must be mounted as
shown in Fig. 4.
6.2. Fitting the wheels (3)
Fit the supplied wheels as shown in Figure 5 and
Figure 6.
6.3. Mains connection:
Before you use the machine, make sure that the
mains voltage complies with the specifi cations on
the rating plate. Long supply cables, extensions,
cable reels etc. cause a drop in voltage and can
impede motor start-up. At low temperatures below
+5°C, sluggishness may make starting diffi cult or
impossible.
6.4 On/Off switch (8)
To switch on the compressor, press the button (8).
To switch off the compressor, press the button (8)
again (Fig. 2).
6.5 Setting the pressure (Fig. 1)
You can adjust the pressure on the pressure
gauge (6) using the pressure regulator (7).
The set pressure can be drawn from the
quick-lock coupling (5).
6.6 Setting the pressure switch
The pressure switch is set at the factory.
Cut-in pressure approx. 8 bar
Cut-out pressure approx. 10 bar

7. Replacing the power cable

If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_TH_AC_240_50_10_OF_SPK7.indb 18
Anl_TH_AC_240_50_10_OF_SPK7.indb 18
GB
8. Cleaning, maintenance and
ordering of spare parts
Important!
Pull the power plug before doing any
cleaning and maintenance work on the ap-
pliance.
Important!
Wait until the compressor has completely
cooled down. Risk of burns!
Important!
Always depressurize the tank before carrying
out any cleaning and maintenance work.
8.1 Cleaning
Keep the safety devices free of dirt and dust
as far as possible. Wipe the equipment with a
clean cloth or blow it with compressed air at
low pressure.
We recommend that you clean the appliance
immediately after you use it.
Clean the appliance regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be
aggressive to the plastic parts in the appli-
ance. Ensure that no water can get into the
interior of the appliance.
You must disconnect the hose and any
spraying tools from the compressor before
cleaning. Do not clean the compressor with
water, solvents or the like.
8.2 Condensed water (Fig. 7)
Important! To ensure a long service life of the
pressure vessel (2), drain off the condensed
water by opening the drain valve (1) each time
after using. To open you must turn the cock on the
drain screw through 90°. Tilt the vessel so that the
drain screw is the lowest point of the vessel and
the condensed water can drain off completely.
To close again, turn the cock back through 90°.
Check the pressure vessel for signs of rust and
damage each time before using. Do not use the
compressor with a damaged or rusty pressure
vessel. If you discover any damage, please con-
tact the customer service workshop.
- 18 -
03.09.13 08:25
03.09.13 08:25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis