Balluff BAW M18MI2-UAC50B-BP05-002 Betriebsanleitung Seite 4

Analog-wegsensor

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

User's Guide
Inductive Analog Sensor BAW M18MI2-UAC50B-BP05-002/004
Nr. 818914 DE/EN Edition B16
Correct switching points in teach-in mode
1 Connect the Control input (C) through a switch to +
(Fig.12).
2 Turn on programming mode: Hold the button down for
at least 5 seconds.
3 Select the switching point to be correcgted: Press the
button for max. two seconds until the next switching
point is selected.
4 Position the target object (machine member etc.) at
the desired switching location.
5 Save the switching distance: Hold the button down for
two to four seconds.
6 Return to operating mode: Press the button for max. 2
seconds as often as required until the LED no longer
flashes.
7 After programming is complete, connect the sensor to
the user-side electronics. In operating mode a fixed
connection between the C input and ground is
recommended.
Characteristic Curves
Curve type -002:
U
a
10V
5V
0
s
min
s
l
e
s
l
LED 1
LED 2
LED 3
Fig. 1: Type -002, Analogsignal im Linearitätsbereich
Curve type -004:
Fig. 2:Analogsignal im Linearitätsbereich
All manuals and user guides at all-guides.com
s [mm]
s
max
l
Technical Data
Type -002
Normally open function of the switching outputs
Type -004
Normally closed function of the switching outputs
Linear range Sl min.
Linear range Sl max.
Non-linearity max.
Effective distance Se
Repeat accuracy
Ambient temperature Ta min.
Ambient temperature Ta max.
Opt. working temperature min.
Opt. working temperature max.
Adjustment indicator
Power-on indicator
Electrical data
Rated operating voltage Ue DC
Operating voltage UB min DC (Ua)
Operating voltage UB max DC (Ua)
Ripple max. (% of Ue)
Rated operating current I
e
for one switching output
All output currents combined
Load capacitance
for one switching output
All load capacitances combined
Hysteresis H max.
Voltage drop Ud at Ie
Rated isolation voltage Ui
Rated supply frequency
No-load current max. Io at Ue
Output voltage at Sl min
Output voltage at Sl max
Output voltage at Se
Load resistance voltage RL min.
Short circuit protected
Miswiring protected
Reverse polarity protected
Mechanical data
Housing material
Surface protection
Tightening torque
Active surface material
Connection type
Cable jacket material
Cable diameter D max.
Cable part number
Cable length
No. of conductors
Cross-section
Cable shield
Enclosure rating per IEC 60529
Shock rating
Vibration rating
Contamination Level
Approvals
* The value may be exceeded as long as the sum of all output
currents is not greater than 60 mA.
** The value may be exceeded as long as the sum of all load
capacitances is not greater than 400 nF.
1
mm
5
mm
±120
µm
3
mm
±8
µm
-10
°C
+70
°C
10
°C
50
°C
no
no
24
V
15
V
30
V
15
%
20*
mA
60
mA
100**
nF
400
nF
0,3
mm
1,5
V
250
VAC
DC
20
mA
0
V
10
V
5
V
2000
Ohm
yes
no
yes
Brass
Nickel plated
25
Nm
PA
Cable
PUR
3.0
mm
LiY11Y-O
5.0
m
7
0.25
mm²
no
IP67
half-sinus 30gn, 11ms
55Hz, 1mm ampl.,
3x30min
3
CE
4