Herunterladen Inhalt Inhalt Diese Seite drucken

Specification - LEMANIA ENERGY FLASH Serie Bedienungsanleitung

Ladegerät / battery support
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
8
ABNORMAL DISPLAY AND TROUBLE SHOOTING
Abnormal condition
No battery detected
Battery short circuit
Inverse battery connections
Voltage is too low
Voltage is too high
Battery bad cell protection
Over-temperature protection
Over voltage control protection
Over current control protection
Bad battery (in Test mode)
Need to charge (in Test mode)
9

SPECIFICATION

Input voltage:
220-240Vac 50/60Hz
Rated output:
12 24Vdc 35A for SF35; 12V Peak- 150A, Continuous 100A for SF150.
Battery type:
Lead acid
Suitable for Battery size:
Operating Environmental:
Storage environmental:
Input cable size:
Output cable size:
Net weight:
Safety Standard :
Dimmensions
Possible cause
Loose connection
Incorrect connection
Incorrect connection
If the Battery voltage is less than 2-
4V, the charger will not start to
recharge the battery automatically
12V batt. set with the 24V mode
Battery has failed
The charger needs to be checked
The charger needs to be checked
The charger needs to be checked
Battery is short circuited or has failed
Deeply discharged or sulphated
battery
(Flooded, AGM, EFB,
GEL.) or lithium (LiFePO4) starter batteries.
20 Ah to 1200 Ah.
-10~40°C, 0-90% RH.
-20~85°C, 0-90% RH.
1.5mm
3C 75°C WITH 3Pin VDE Plug plus IEC-60320-C19.
2
3meter 8mm
105°C with clamps for SF35.
2
3meter 25mm
105°C with clamps for SF150.
2
Approx. 5.0 Kg for SF35; Approx. 9.0 Kg for SF150.
EN 60335-1, EN 60335-2-29, EMC Standards: EN55014
SF35 (Lx Wx H: 270*243*109mm)
SF150 (Lx Wx H: 330*328*109mm)
Suggested solution
Check the battery and terminal connections
Check the battery and cables connections.
Reverse the polarity of the connection to the
battery
Press and hold
the charging process to start
(Check the connections before activating this function)
Change to the correct 12/24V mode
Replace the battery
Contact your distributor
Contact your distributor
Contact your distributor
Replace the battery
Use the Charge mode to recharge the battery
14
for 3 seconds to force

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Flash sf35Flash sf150Flash 35F35F150

Inhaltsverzeichnis