Herunterladen Inhalt Inhalt Diese Seite drucken

LEMANIA ENERGY FLASH Serie Bedienungsanleitung Seite 11

Ladegerät / battery support
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
Equalization: In this stage a higher voltage and low current is applied in order to balance the internal cells of the battery (only
for Lead acid batteries).
Maximum equalization stage voltages for each battery chemistry:
AGM BATT
EFB BATT
Flooded BATT
Equalization current control
x2 for 24V mode (SF35 only)
Remarks: the interface will display 80~99% charged during the Absorption and Equalization stage.
Float:
Compatible only with Lead Acid batteries this stage is used for long term battery maintenance.
Float voltage: 13.6v
Remarks: the interface will display 100% charged during the Float stage. If the voltage falls below 12.5V then the charger will
automatically return to the Bulk mode.
LiFePo4 Recharge Stage: If the battery voltage falls below 12.8V the charger will automatically return to the Bulk mode.
If AUTO-DETECT is ON: the charger will automatically restart the charging process from where it was interrupted in case of a
cut in AC power.
for Lead acid batteries).
14.5V
14.6V
15.5V
15% of Bulk Current
11