7. Rotate the device back to its normal position (control panel facing up)
8. If the purifier indicated, with the FILTER RESET control lamp (4f), that it is necessary to replace
the filter, press the ON/OFF button (4a) and keep it depressed for 5 seconds. The filter's con-
trol lamp will reset and be deactivated.
NOTE! The filter itself cannot be dismantled and any attempts to separate the individual filters (initial, HEPA,
carbon) will render it damaged.

USING THE APPLIANCE

1. Place the device on a dry, flat and stable surface. Make sure there is enough free space around
the device to ensure unobstructed air circulation. The device may only work in a vertical posi-
tion, its control panel facing up.
2. Connect the power cord to the mains.
3. Start the purifier with a button (4a). The device starts purifying the air and signals its with a
control lamp (4e).
4. Adjust the air purification rate with the button (4d). Three speeds are available: "I" – low
speed, "II" – average speed, "III" – high speed. The selected purifying speed is indicated by
a relevant control lamp (4j). There is also a "TURBO" mode available, signalled by all control
lamps on at the same time (4j).
5. A UV-C germicidal lamp and air ionizer is activated with a button (4c). The operation of the
UV-C lamp and air ionizer is signalled by a control lamp (4h). The same button (4c) can be
used to activate the Sleep mode. Once this mode is selected, the control lamp (4j) flashes
at first and then the Sleep mode is activated. All control lamps are deactivated and the pu-
rifying rate is reduced in this mode. The Sleep mode is deactivated once the button (4c) is
pressed again.
6. The Timer button (4b) can be used to set the time after which the device stops filtering the air
and is deactivated. The available times are: 2, 4 and 8 hours. The selected time for automatic
deactivation is indicated by a relevant control lamp (4g). To deactivate the Timer mode, press
the button (4b) until the control lamps are off (4g).
7. Once your work is done, deactivate the device with the button (4a) and unplug it from the
mains.

CLEANING AND MAINTENANCE OF THE DEVICE

CAUTION! Unplug the device from the mains before any cleaning or maintenance operations.
CAUTION! Do not submerge the device in water or other liquids.
CAUTION! Do not use any aggressive cleaning agents, gasoline, solvents etc. to clean the device.
CAUTION! Clean the device at least monthly.
1. Use a damp and gentle cloth to clean the device's housing and wipe it dry afterwards. Use a
mild cleaning agent for stubborn dirt.
2. The integrated filter (7) can be periodically dusted with a damp cloth from the side of the
initial filter (externally). Do not submerge the filter in water, do not dust it and do not disas-
semble it. If the air purifier indicates that a filter replacement is necessary, with the Filter Reset
lamp (4f), replace the filter with a new one (see: FILTER INSTALLATION AND REMOVAL DE-