1.
Housing
2.
Air intake grate
3.
Air exhaust grate
4.
Control panel
a.
On/off touch button
b.
Timer touch button
c.
UV lamp and Sleep mode touch
button
d.
Air filtering rate touch button
e.
Air purifier (ON/OFF) control lamp
f.
Filter reset control lamp
APPLICANCE FEATURES
The air purifier is an appliance for end-to-end treatment of the indoor air you breathe. The air is
purified with a three-stage filter bank (comprising a prefilter, a HEPA filter and an activated carbon
filter). Each of the three filter stages has a unique function. The air purifier also includes a UV-C
lamp and an air ionizer.. Initial filter is located in the integrated filter's external circuit, the HEPA
filter is located inside the integrated filter and the carbon filter is located in the internal circuit.
Prefilter: pre-filtering of air to remove dust, allergens and hair from the air.
HEPA filter: main filtering of air to remove remaining dust, pollens, allergens, mould spores
and smoke.
Carbon filter: filters out formaldehyde, benzene, harmful airborne gases and all bad odours.
UV-C lamp: biological treatment of air by killing viruses, bacteria and microbes.
Ionizer: the ionizer generates negative ions to regulate the ionic balance of indoor air and
improve your well-being by generating the air present at natural locations, e.g. in a forest or
at the seaside.
BEFORE FIRST USE
1. Unpack the air purifier, remove all bags, fillers and transport interlocks.
2. Make sure the electrical mains parameters match the data on the device's name plate.
3. Make sure the integrated filter (7) remains in its place, inside the purifier, and that its
protective film is removed.
REMOVING AND INSTALLING THE FILTER BANK
1. Make sure the device is not connected to the power supply.
2. Rotate the device by 180 degrees, so that the cover (5) faces
upwards.
3. Unscrew the nut (6) and remove the cover (5).
4. Take out the integrated filter (7) from the housing (8).
5. Install a new filter in the housing (8). Remove the protective
film from the new filter, if used.
6. Install the cover (5) and turn the nut (6).
g.
Timer control lamps (2 hrs, 4 hrs,
8 hrs)
h.
UV-C control lamp and ionizer
(UV-C/ION)
i.
Sleep mode control lamps
j.
Airflow rate control lamps (I,II,III)
5.
Filter housing cover
6.
Filter housing cover nut
7.
Integrated filter
8.
Integrated filter housing
9.
UV lamp housing
Filter disassembly schematics