Beta-BT Heaters
ENG

Installation and Operating Instructions

1. Safety Instructions
Electrically skilled person
The installation must only be done by an electrician with the appropriate qualifications.
This manual is a part of the product and must be stored in a safe location and be available for future
installation and service.
WARNING
Danger of electric shock! Risk of fire!
Improper installation can cause personal injury and property damage.
Disconnect the power supply before carrying out any installation or maintenance work on this heater.
Do not operate a defect heater.
In order to avoid overheating, do not cover the heater, figure 1.5.
If the supply cord is damaged, it must be replaced by the manufacturer or electrically skilled person.
CAUTION
People who are not able to operate according to this manual must not use this appliance.
Some parts of this heater can become very hot and cause burns. Particular attention has to be where
children and vulnerable people are present.
Children of less than 3 years should be kept away unless continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on / off the heater provided that
it has been placed or installed in its intended normal operating position and they have been given
supervision or instruction concerning the use of the heater in a safe way and understand the hazards
involved. They shall not plug in, regulate and clean the heater or perform user maintenance.
2. Installation instructions
The heaters are intended for permanent installation on the wall rack included in the package, figures 1.1
- 1.4.
Do not install the heater immediately below a socket outlet, figure 1.5.
Connect the heater according to the wiring diagram, figures 2a and 2b. The heaters are double-insulated,
class II. Separate earth is not required.
Models with a connection box are possible to control with an external voltage. Connect the external voltage
to the connector 4. Any phase can be used for the external temperature control.
The heaters are equipped with an electronic thermostat.
The dripping water protected BETA IP21 heater must not be installed in places in which it can be subjected
to spraying water.
The splashproof BETA IP24 heater must not be installed in places in which it can be subjected to water jets.
When the BETA heater is installed in a bathroom, the switch and other controls must not be within the
bather's reach.
3. Control Panel, figure 3
A
Power switch
B
Blue LED indicator
C
Red / Green LED indicator
D
Adjustment knob
E
Pairing the heater with mobile device / Factory reset