Herunterladen Inhalt Inhalt Diese Seite drucken

Wessamat CombiLine W80 Bedienungsanleitung Seite 69

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

User manual - English
Machine runs, but does
not produce ice
Ice cube maker not run-
ning despite power plug
switched on / safety
switch ('Pressostat') has
triggered
Tub is overfilled with
water / water overflow-
ing
Ice cubes are cloudy
User-manual-CombiLine-W80-W120-W240-0299-2
1. Leak(s) in the cooling
system
2. Compressor faulty
3. Hot gas valve faulty
(valve no longer closes)
1. Condenser is soiled
2. In water-cooled ma-
chines, the water supply
may be interrupted
3. In water-cooled ma-
chines, the condenser or
cooling
water controller
scaled (lime).
4. Insufficient air circula-
tion for air-cooled ma-
chines
5. Fan no longer running
1. Water inlet valve does
not close
2. Probe cable(s) inter-
rupted
3. Fault in water sensor
electronics
Tub motor no longer run-
ning
1. Locate and rectify leak(s) in the
cooling system
2. Replace compressor
3. Replace hot gas valve
1. Clean condenser
2. Open water supply
3. Descale condenser or cooling wa-
ter controller, or replace if necessary
4. Check distances of the machine
to the side walls and the rear, en-
sure ventilation according to the
specification
5. Replace fan motor
1. Replace water inlet valve
2. Measure electrical conductance
of the individual cables, rectify inter-
ruption, replace probe if necessary
3. Replace water sensor electronics
Check tub motor voltage. If voltage
is present and the tub motor does
not turn, replace the tub motor
Kippmotor
Seite 69

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis