Herunterladen Inhalt Inhalt Diese Seite drucken

SUEVIA DigiLog Bedienungsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Abb.1 / FIG.1
Abb.2 / FIG.2
L
~
1
2
3
N
DigiLog
Abb.3 / FIG.3
3000 W
1200 VA
2000 VA
3000 W
600 VA
400 VA
90 VA
Abb.5 / FIG.5
65
60
ORBIS Zeitschalttechnik GmbH
Robert-Bosch-Straße 3 D-71088 Holzgerlingen
Telefon 07031/8665-0 Fax 07031/8665-10
E-mail: info@orbis-zeitschalttechnik.de
http://www.orbis-zeitschalttechnik.de
DigiLog / DigiLog 2
1
2
0
3
6
9
12 15 18 21 24
3
4
5
6
7
RESET
MENU
C1
C2
C
8
10
9
4
5
6
L
ON
C1 ON 1 - 2
~
C2 ON 4 - 5
1
2
3
N
DigiLog 2
Abb.4 / FIG.4
35
ENG
FIG.1
1. Time scale
3. Text line
5. Hour / Date
7. C1 relay status symbol
15
9. Go up / C2 manual operation
11. Accept option / Enter the menu / Switch
on the device without power
13. C2 manual operation (blinking) /
14
C2 permanent manual (fixed)
15. Days of the week
13
OPERATING INSTRUCTIONS
DigiLog / DigiLog 2 is a digital time switch designed to control any electrical installation.
12
It offers the possibility of performing different types of operations: ON and OFF at a set time, short-
term operations or pulses (1 to 59 seconds), and repetitive cycles (1 to 59 seconds or 1 minute to 23
hours and 59 minutes). All of them can be applied to channels C1 and C2 with DigiLog 2.
Furthermore, it includes a series of additional functions such as: automatic DST changes, 4 holiday
periods and adjustable screen brightness.
Menus can be displayed in several languages and they show the schedule for the current day on
screen.
11
With 1 (DigiLog) or 2 (DigiLog 2) independent and voltage-free circuits switched, which allows the
programming of up to 40 operations between channel 1 and/or channel 2.
INSTALLATION
WARNING: Installation and mounting of electrical devices must be carried out by an authorised fitter.
BEFORE PROCEEDING TO THE INSTALLATION, REMOVE POWER SUPPLY.
The device is internally protected against interference by a security circuit. However, some
particularly strong electromagnetic fields may alter its functioning. Interference can be avoided if the
following installation rules are taken into account:
- The device must not be installed near inductive loads (engines, transformers, contactors, etc.)
- It is advisable to devise a separate line for supply (provided with a network filter if necessary).
- Inductive loads must be provided with interference suppressors (varistor, RC filter).
If the time switch is used in combination with other devices in an installation, it should be made sure
that the constituted unit does not generate extraneous disturbances.
RESTORE SUPPLY ONCE THE DEVICE IS FULLY INSTALLED.
MOUNTING
Electronic control device of independent mounting in fuse box, with 35 mm. symmetrical profile,
according to EN 60715 standard (DIN Rail).
CONNECTION
Connect power supply according to the diagram in FIG.2.
Phase and Neutral positions must be respected, checking the connections made. A wrong
connection may destroy the device.
START-UP
THE DEVICE MUST BE POWERED to be able to execute the installation control. When this
happens, the display will light up and the MAIN screen will appear.
When the device is not powered the display remains off, storing all the date and time programming
during the power-reserve period (4 years) thanks to the incorporated lithium battery. If installed
without battery, the device has a security power-reserve of approx. 48 hours.
With the device unpowered, when pressing the MENU
allow programming. If after 5 seconds no key is pressed, the display will be turned off again.
These devices have four keys for their setting and programming.
The display shows the following information:
 Schedule with the day's operations (except on holidays). A schedule for each channel with 24
divisions in which each segment represents 1 hour ON.
 The display has a text line that will show the following information alternatively:
Current date  PERMANENT operation  Active HOLIDAY period
 Complete time.
 Manual operation symbol
is PERMANENT the symbol is fixed.
 State of C1 / C2 circuits: ON
SETTINGS
DigiLog / DigiLog 2 are factory programmed with the current date and time, and configured as
follows:
 Time Mode:
 Standard to DST change:
 DST to Standard change:
 Holidays:
 Programs:
MANUAL OPERATION
Activated or disabled, temporarily reversing the state of the circuits manually from the main screen,
by pressing the ▼ C1 or ▲ C2 keys.
The symbol
will appear blinking on screen over the handled channel until we press ▼ C1 or ▲
C2 again, returning to the previous state.
PROGRAMMING
Programming is based on menus and submenus through which we can move to program operations
or adjust the device. The main menu can be accessed from the standby screen by pressing ✓. With
keys ▼ and ▲ we will move through the different menus and by pressing ✓ we will access them. To
go back to the previous menu we press C.
The details to be programmed always appear blinking on screen.
The structure of the menus is the following:
PROGRAMS
2. Schedules
4. Low-battery symbol
6. C1 manual operation (blinking) /
C1 permanent manual (fixed)
8. Scroll down / C1 manual operation
10. Cancel option / Go back
12. C2 relay status symbol
14. 12 H / 24 H
key, the display temporarily lights up to
. It blinks when a manual switching is activated and if the switching
, OFF
24 h
Automatic (last Sunday of March)
Automatic (last Sunday of October)
NO (all 4 periods disabled)
None
✓
ENTER
✓
PXX
✓
DELETE
EDIT
✓
✓
NO TO ALL
TYPE
✓
YES TO ALL
CHANNEL
TIME SWITCH
DELETE

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Digilog 2

Inhaltsverzeichnis