automatically enter protection status; if the temperature of the
exhaust pipe rises to a certain temperature, it can automatically
revert to normal operation.
3.2、Overflow Protection Function:
When water in the water pan exceeds the warning level, the machine
will automatically sound an alarm, and the "FULL" indicator light will
flash. At this point, you need to move the drainage pipe connecting
the machine or the water outlet to sewer or other drainage area to
empty the water (details see Drainage Instructions at the end of this
chapter).When the water is emptied, the machine will automatically
return to the original state.
3.3、 Automatic Defrosting (only in cooling models ): The machine has
automatic defrosting function.Defrosting can be achieved through
four - way valve reversing.
3.4、Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute
delay booting protection function after the compressor is turned off.
V.Installation and adjustment
1.Installation:
Warning: before using the mobile air conditioning, keep it upright for at
least two hours.
The air conditioning can be easily moved in a room. In the process of
removing, ensure that the air conditioning is in a upright position and the
air conditioning should be placed on a flat surface. Do not install and use
the air conditioning in the bathroom or other humid environment.
1.1 Install the heat pipe assembly (as shown in Fig.1)

Werbung