4.5 General notes regarding danger and problem solving
Risk of Accident
Make sure that the seal is set correctly in the groove before each starting up of the
vacuum suction.
Always place the vacuum suction in a way that the seal cannot be damaged or taken
out of the groove.
Change the seal in time. Vacuum can be reduced due to dust, shavings etc.
Exchange the seal when it starts getting porous.
With small work pieces you can use only half of the vacuum plate.
Not for MDF plates.
Only even plates can be clamped.
No solid wood.
Please check adhesion (vacuum) fi rst when clamping vertically.
For large work pieces larger than ca. 1.2 m an additional extension module with a
connector can be used.
Vertical holding force is 85 kg.
Malfunction
Necessary vacuum not
reached.
All manuals and user guides at all-guides.com
Operating Manual
and Service Notes
VACUUM CLAMP
WARNING
Cause
Hose and/or tube connec-
tions are not close
Close gate valve
Improper support (not gas-
tight, uneven)
Seal not in groove
No electricity or compressor
failure
Seal on the lower side of
support is damaged
23
Action
Check tightness of connec-
tions
Change gate valve
Use airtight support
Push in seal
Exchange seal