INSTALLATION
Installation
Note
To prevent disturbance due to structure-borne noise
transmission, never install the wall mounting bracket
on the external walls of living areas or bedrooms.
f Install the wall mounting bracket on a garage
f
wall, for example.
Note
To facilitate installation and maintenance work, we
recommend a maximum installed height of 1 m.
f Mark out the positions of the holes to be drilled on the
f
wall. To do this, hold the wall mounting bracket against
the wall at the required installation height.
Material losses
!
Ensure that no cables/water pipes are damaged
through drilling the holes.
4. Installation
4.1
Securing the assembly to the wall
f Drill the holes.
f
f Insert rawl plugs into the holes.
f
f Secure the wall mounting bracket to the wall.
f
Material losses
!
Ensure that the wall mounting bracket is flush with
the wall.
f Check the wall mounting bracket is straight using a spirit
f
level.
f If necessary, level the wall mounting bracket by loosening
f
and retightening the screws.
f Tighten all the bolts securely with a spanner.
f
4.2 Securing the outdoor unit
Note
Lifting straps to transport the appliance can be hooked
into the area highlighted in grey at the bottom of the
support frame.
WK 2
f Undo the appliance feet from the outdoor unit. Dispose of
f
the appliance feet.
f Screw the rubber buffers into the illustrated positions on
f
the outdoor unit.
Material losses
!
Ensure that the outdoor unit does not slip from the
wall mounting bracket during installation.
f Place the outdoor unit with its anti-vibration mounts onto
f
the wall mounting bracket.
f Insert the screws with washers and retaining clips into the
f
rubber buffers. Ensure that the retaining clips are aligned
at right angles to the wall bracket.
f Tighten all screws.
f
f Attach the end caps to the ends of the wall mounting
f
bracket.
Material losses
!
Have a qualified contractor check the installation to
ensure that the appliance is permanently and securely
installed.

5. Specification

5.1
Data table
Support length
mm
Weight
kg
Suitable for
WK 2
234722
800
175
15/20/25 AC(S), HPA-O Premium
| 5