All manuals and user guides at all-guides.com
Maintenance and Cleaning
Use only a moist cloth to clean the unit. Do not use
aggressive chemicals as benzene or thinner, which may
dissolve plastic parts, or abrasives.
Do not touch and do not clean the gas sensor.
Do not use the device any further if it has become
defective.
Power source:
Working current:
Response time:
Detectable gases:
Low alarm stage:
High alarm stage:
Working temperature:
Working humidity:
Dimensions:
Weight (w/o batteries):
Operation
Technical Data
2 x LR6 (AA)
139 mA
Approx. 5 sec.
Natural gas (Methane), LPG
(Propane, Butane) etc.
combustible gas
20 +/- 5 % LEL
50 +/- 10 % LEL
-20º C – 55º C
< 95% RH
Ø29 x 193 mm
Approx. 43 g
15