Don't wash the appliance with direct or high pressure jets of water.
•
To disconnect the appliance in case of breakdown or bad functioning, closing the general
•
gas cock and disconnect it from electrical system.
Every maintenance operation, every repairs or substitution, must be done from qualify
•
staff or assistance centre. Use only original spare parts.
Do not obstruct air vents or heat dissipation openings.
•
2.2 Top burners
In the following figure are represented burners employed in this appliance range:
•
Type G
burner
Type M
burner
Type P
burner
To push the knob corresponding to the selected burner, turn it in anticlockwise on
•
position On (Spy Position–Symbol: Little Star), than light (with a match) the spy under
the burner in order to light up the pilot flame. Hold pressed the knob for 10 second to
allow the safety device intervention than release the knob; the spy must keep lighted on
the contrary repeat this operation.
Back burner
Index
Ø128 mm
Ø104 mm
Ø 72 mm
G
●
Spy Pos.
Max. Pos.
Min. Pos.
26/72
power 7.25 kW, double crown
power 6.0 kW
power 3.5 kW
M
P
Front burner
Index
●
Spy Pos.
Max. Pos.
Min. Pos.
mod. G02