Oven burner
To remove the front low band metal sheet placed under oven
door, to enter on injector oven burner.
To unscrew the burner nozzle and replaced it with the one
adapted to the type of used gas consulting table 1 on section
"Oven".
To substitute the nozzle of oven spy: unscrew the cap–screw,
then unscrewing completely the nozzle and replace it with the
one adapted to the type of used gas consulting table 3. To screw
the nozzle till to bottom. To reassemble the cap–screw and the
seal washer.
Tab. 3
Butane/Propane
Methane G20
40
To substitute the by-pass minimum of oven valve: the minimum by-pass to substitute as
instruction of table 4.
After the substitution to seal the by pass with varnish.
Tab. 4
Burner
Oven kW 8.4
Maxi oven Kw 11
Prime air regulation
To regulate prime air of all burners: to place the regulation ear-ring air to the measures
illustrated on following drawings.
G30/G31
20
Methane
Butane/Propane
G20
G30/G31
200
110
220
120
Tab. 5
Burner
kW 7.25 A = mm
A
kW 6.0 A = mm
kW 3.5 A = mm
Valve By-pass
Methane
G20
2 mm
All
open
24/72
mod. G02
Oven pilot nozzle
Butane/Propane
G30/G31
All
open