Top burners
To unscrew the nozzles of the plan burners and to replace them with those adapted to the
type of used gas consulting table 1.
To extract the nozzles spy pilot burners inserted on particular
illustrated plan in the figure, to unscrew the gas tube
connected to spy; it's advisable to use contemporary the
spanner nr.10 and nr.12.
To substitute the nozzle of spy pilot plan burners with the one
adapted to the type of used gas consulting table 2.
Tab. 2
To regulate the minimum of burners with the by-pass screw as indicated on figure: for
BUTANE/PROPANE gas (G30/G31) the screw must be screwed till the bottom;
By-pass
Tab. 1
Burner
kW 7.25
kW 6.0
kW 3.5
Oven kW 8.4
Maxi oven Kw 11
Methane
Butane/Propane
G20
G30/G31
35
20
for gas METHANE (G20)
place the burners knob to regulate, in minimum position
with the burner light up, to unscrew anticlockwise the by-
pass screw to obtain a minimum steady flame. The burner
flame's must remain ignited also in the passages from
maximum to minimum without cause backfires.
After the regulation seal the by pass with varnish.
Methane
Butane/Propane
G20
G30/G31
200
180
145
220
280
23/72
mod. G02
132
125
95
140
170