SWITCHING THE FLUE CONNECTION
If the flue exit is located on the rear of the stove:
1.
Lift the lid.
2.
Remove the rear plug (no longer required).
3.
Remove the baffle plate to make it easier to remove the
flue collar (torx screw).
4.
Remove the collar.
5.
Switch the collar and the rear blanking plate.
6.
Mount the cover in its original position.
7.
Put the plug (supplied) in the cover.
Take care not to damage the paint.
CONNECTING THE FLUE PIPE
Treat this point of the installation with care and attention in
accordance with DTU 24.1. This appliance must not be connected
to a shared flue system. For ducts that are already in place: get it
cleaned (mechanical chimney brush). Get an authorised stove-
maker to check it for soundness and suitability (stability, air
tightness, compatibility of materials, diameter, etc.). If the flue is
not compatible (old, cracked, considerable blockage): - contact a
specialist so that it can be repaired in order to comply with the
regulations in force.

CONNECTING PIPES

Use T450 vitreous enamelled pipes (minimum) or 316 stainless
steel (available at your stockist), without shortening them.
The connection to the flue must be made in the room in which the
appliance is installed. Provide access for chimney sweeping and to
clean the flue pipe.
The pipe must not stick out of the flue pipe and the connections
must be removable and airtight.
Avoid having a long horizontal section in front of the flue. If this is
inevitable, then give it a rising slope of 5 cm per metre.
COMBUSTION AIR CONNECTION
Outdoor air intake not connected
If it is not possible to connect the collar to an outdoor air intake,
then it will be necessary to get an additional fresh air intake
positioned facing the prevailing winds to permit correct
combustion, particularly if the house is heavily insulated and/or
fitted with a controlled mechanical ventilation system (C. M.V.)
Minimum air passage of 1 dm². Do not operate the stove if a
smoke extractor hood is operating.
If the house does not have a ventilation system that is based on
the air sweeping principle (in accordance with Spanish decree of
March 1982), then the air inlet must be free from obstruction.
Outdoor air intake connected
This stove has been designed for highly insulated rooms. A Ø 75
outdoor air connection is fitted as standard in the bottom of the
stove. This ensures that the combustion air is drawn from outside
and not from the room. This increases the performance of the
system. Furthermore, the combustion will not be affected by the
controlled mechanical ventilation (CMV) system or by a possible
extractor hood.
Principles for the supply of combustion air:
1) Directly through the room wall to the outside.
2) Through a duct that ends in a sanitary vacuum; the section of
the sanitary vacuum ventilation grid (in cm²) must be equal to 5
times the surface area of the same (in m²).
3) Through a buried pipe (with 1 elbow > 90° max.); for an
additional elbow, shorten the max. length of the pipe by 1 m.