11.5 • Endura
Twist 2x5
®
11.5.1 • Endura
Twist 2x5 - without demand control
®
Endura
Twist 2x5 - without demand control
®
Supplier's name or trademark
Reference model
Energy efficiency class
SEC - warm climat
SEC - average climat
SEC - cold climat
Declared typology
Type of drive installed
Type of heat recovery system
Thermal efficiency
Maximum flow rate
Electric power input of the fan drive, including any motor
control equipment, at maximum flow rate
Sound power level L
WA
Reference flow rate
Reference pressure difference
SPI
Control typology
CTRL
Declared maximum internal leakage rates
Declared maximum external leakage rates
Recirculation
Mixing rate of non-ducted bidirectional ventilation units not
intended to be equipped with one duct connection on either
supply or extract air side
Position and description of visual filter warning for RVUs
intended for use with filters, including text pointing out the
importance of regular filter changes for performance and
energy efficiency of the unit
Instructions to install regulated supply/exhaust grilles for
natural air supply/extraction
Internet address for pre-/dis-assembly instructions
For non-ducted units only: the airflow sensitivity to pressure
variations at + 20 Pa and – 20 Pa
For non-ducted units only: the indoor/outdoor air tightness
in m³/h
AEC (Annual Electricity Consumption)
AHS (Annual Heat Saved) - cold climat
AHS (Annual Heat Saved) - average climat
AHS (Annual Heat Saved) - warm climat
(1) Not available, method to be determined.
V E N T I L AT I O N
Renson
S U N P ROT E C T I O N
Maalbeekstraat 10 • IZ 2 Vijverdam • B -8790 Waregem • Belgium
O U T D O O R
Tel. +32 (0)56 62 71 11 • info@renson.be • w w w.renson.eu
Without filter
Endura Twist 2x5
- 13.42 kWh/m²a
- 36.00 kWh/m²a
- 75.43 kWh/m²a
0.152 W/(m³/h)
2.09 kWh electricity/m²a
®
Headquarters
Endura
Endura
Coarse 45% (G3) filter
Renson Ventilation nv
Endura Twist 2x5 - G3
A
A
- 12.82 kWh/m²a
- 35.40 kWh/m²a
- 74.83 kWh/m²a
BVU
variable speed
regenerative
78%
135 m³/h
120 m³/h
23.1 W
23.2 W
52 dB(A)
51 dB(A)
95 m³/h
84 m³/h
10 Pa
0.169 W/(m³/h)
manual control (no DCV)
1.00
not applicable
not applicable
(1)
not yet known
not applicable
www.renson.eu
www.renson.eu
< 5% x Q
not yet known
2.33 kWh electricity/m²a
80.65 kWh primary energy/m²a
41.23 kWh primary energy/m²a
18.64 kWh primary energy/m²a
Product sheet
Twist
®
Twist 2x5
®
WITHOUT DEMAND CONTROL
ePM1 80% (F7) filter
Endura Twist 2x5 - F7
A
- 11.71 kWh/m²a
- 34.30 kWh/m²a
- 73.72 kWh/m²a
98 m³/h
22.4 W
54 dB(A)
69 m³/h
0.201 W/(m³/h)
max
2.77 kWh electricity/m²a
en
83