Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Contents Of Delivery - BWT Multiblock X Einbau- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Multiblock X:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. Technical data

Multiblock X
Nominal width
Nominal pressure (PN)
Flow rate at p = 0,2 bar
Water temperature, max.
Ambient temperature, max.
A – Connection width
B – Overall length without fitting
C – Overall length with fitting
D – Centre of pipe to connection
E – Centre of pipe to handwheel (open position)

2. Contents of Delivery

-
Connection fitting, including bypass, integrated
backflow preventer and bleed valve
-
Screw-in part
-
Connection screw
3. Purpose
The X multiblock enables the efficient and low-cost
installation of softeners or limescale protection sys-
tems, eliminating the need to fit the usually essential
bypass pipe with the attendant stagnant water and
appropriate fittings.
Note: This is a maintenance shut-off while super-
vised servicing, inspection or other work is carried
out, and does not involve the permanent shutting-
off of a valve.
Flow rate curve Multiblock X
flow rate with filter element DN25
differential pressure in bar
1"
DN
25
bar
10
m³/h
1,45
°C
30
°C
40
mm
60
mm
122
mm
204
mm
45
mm
101
flow rate with filter element DN32
The installation of the system and the required mo-
difications should only be carried out by the water
utility or an installation company registered in the
water utility's directory of installers, in accordance
with the AVB Wasser V (General Insurance Terms),
§12.2.
4. Function
The water inlet to the softening or limescale protec-
tion system can be interrupted with the brass X mult-
iblock. In this case, the water supply is maintained
by the integrated bypass (see fig. 4) so that mainte-
nance work, for example, can be carried out.
EN
5/4"
32
10
2,4
30
40
60
122
218
45
101
9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis