Herunterladen Inhalt Inhalt Diese Seite drucken

Blaupunkt 5IE64252 Bedienungsanleitung Seite 62

Kochfeld autark, induktion
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Models 3 and 4 heating zones: 5IE64252, 5IE84252, 5II84251, 5IB64211
Mains
230V~50/60Hz
400V~ 50/60Hz
( * ) as per standard EN 60 335-2-6
Connecting the hob
For the various connection options, use the brass terminal bridges located in the casing.
Single-phase connection 230V~1P+N:
Place a terminal bridge between terminals L1 and L2, then between terminals N1 and N2.
Connect the earthing to the « earth » terminal, the neutral to terminal N1 or N2, and phase L to
terminal L1 or L2.
Two-phase connection 400V~2P+N:
Place a terminal bridge between terminal N1 and N2.
Connect the earthing to the « earth » terminal, the neutral to terminal N1 or N2, phase L1 to
terminal L1 and phase L2 to terminal L2.
Model 5 heating zones: 5II94291
Mains
230V~50/60Hz
400V~ 50/60Hz
400V~ 50/60Hz
( * ) as per standard EN 60 335-2-6
Connection
1 phase + N
2 phases + N
Connection
1 phase + N
2 phases + N
3 phases + N
Diameter
3 x 2.5 mm²
4 x 1.5 mm²
Diameter
3 x 2.5 mm²
4 x 1.5 mm²
5 x 1.5 mm²
30
Cable
Fuse
H 05 VV - F
25 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F
Cable
Fuse
H 05 VV - F
25 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F
H 05 VV - F
16 A *
H 05 RR - F

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

5ie842525ii842515ii942915ib642115iz34291

Inhaltsverzeichnis