WARNING! It is strictly forbidden to remove the table by lifting it from the top (mattress).
WARNING! Do not use knives or box cutters to open the box so as not to risk damaging the
table and in particular the pudding.
2.2. Flooring
The floor on which the table will be placed must be solid, smooth, horizontal and adequate to support its weight and
ensure the stability.
2.3. Lighting
The user must ensure that the lighting of the work areas is sufficient to allow a good view of the operations and all
elements of the table; the level of lighting should be in accordance with the UNI EN 12464-1; in particular should be
avoided shadows and annoying glare.
2.4. Positioning
The position of the table compared to fixed obstacles must be such as to allow the easy passage for the use and
maintenance; in particular, the minimum space to allow the passage of persons shall be equal to 650 mm (in accor-
dance with UNI EN 349:2008). To prevent crushing of the whole body the minimum distance between the leg rest
fully stretched and the back completely lowered and fixed obstacles must be equal to 500 mm.
2.5. Power supply
The system of power supply must have voltage and frequency equal to the rated voltage and frequency of the power
supply of the device and be appropriate to the installed capacity, as indicated on the identification plate of the table.
The power supply must be supplied to the unit by a line:
Protected against overcurrent by an automatic circuit breaker (circuit breaker) or fuses, properly sized; the ope-
rating current of the protections must be as low as possible taking into consideration the maximum absorption
of the device;
Equipped with a device sensitive to insulation failure (differential) with operating current low enough; this device
must be positioned downstream of the overcurrent protective device (or be integrated with it); Having cables
with section suitable for the power absorbed by the appliance.
The table must also be connected to an external unipotential protection circuit (grounding)
adequate.
Voltage
110/240 V
50/60 Hz
Frequency
3 A max
Absorption
Primary 230V - 110V
Transformer
Secondary 25V 120VA
Duty cycle
18 off on - 2 min on