Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 49
Refer to Fig. 11.
-
Extend the plunger until the spring collet (1) is just visible.
CAUTION
Extending the plunger too far results in damage of the spring in the cylinder.
-
Remove the spring collet with a punch.
-
Fit the new blade (2) using the spring collet.
Replace a damaged fixed blade:
Refer to Fig. 12.
-
Release the cap screw (1).
-
Place the new blade (2) in the recess.
-
Install cap screw (1) and slightly tighten it.
-
Connect the cutter to a hydraulic pump.
-
Extend the moveable blade until it pushes against the fixed blade at full pressure.
-
Depressurize the pump
Apply grease to the blades.
8.5
Yearly dealer maintenance
We recommend having the equipment inspected, checked, set and tested once a year by a Holmatro
Certified Technician who has the appropriate knowledge and the necessary tools (see also section 1.7).
The Holmatro dealer can organize the yearly maintenance for you on a contract basis.
8.6

Long term storage

Ensure that the equipment is completely depressurized.
Store the equipment in a dry, well-ventilated area. Use additional preservatives on the external steel
parts.
9
Decommissioning/Recycling
At the end of its service life the equipment can be scrapped and recycled.
Make sure that the equipment is put out of order to avoid any use.
Check that the equipment does not contain any pressurized components.
Recycle the various materials used in the equipment such as steel, aluminium, NBR (Nitrile
Butadiene Rubber) and plastic.
Collect all dangerous substances separately and dispose of them in an environmentally responsible
way.
Consult the Holmatro dealer about recycling.