TECHNICAL DATA

Electric leaf blower
Rated voltage
Frequency
Nominal input power
No-load speed
Suction performance max
Chopping rate
Collection bag capacity
Weight netto / + Collection bag
Protection class
Protection
Noise information
Measured according to
Sound pressure level L
Sound power level L
2)
WA
Vibration information
Vibration total values (triaxial vector sum) determined according to ISO EN 15503,
Uncertainty K = 1,5 m/s
Vibration emission value a
Subject to technical alterations and amendments.
Warning: The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ.
This may significantly increase the exposure level over the total working period.
The vibration emission level will vary because of the ways in which a power tool can be used and may increase
above the level given in this information sheet.
The vibration emission level may be used to compare one tool with another.
It may be used for a preliminary assessment of exposure.
An estimation of the level of exposure to vibration should also take into account the times when the tool is
switched off or when it is running but not actually doing the job. This may significantly reduce the exposure level
over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool
and the accessories, keep the hands warm, organisation of work patterns.
SAFETY WARNINGS
Read and understand the operating instructions
before using the appliance. Familiarise with the control
elements and how to use the appliance properly. Abide by
all the safety measures stated in the service manual. Act
responsibly toward third parties.
The operator is responsible for accidents or risks to third
parties.
In case of any doubts about connection and operation
refer please to our customer center
You can also download these instructions in digital form
on the internet on our homepage.
14
EN 15503, Uncertainty K = 2,5 dB (A);
1)
1)
pA
2
h
2000/14/ EG;
2)

General Power Tool Safety Warnings

WARNING Read all safety warnings and all
instructions. Failure to follow the warnings
and instructions may result in electric shock, fire
and/or serious injury.
Save all warnings and instructions for future
reference.
The term „power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-
operated (cordless) power tool.
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
IEWV 3500
230-240 V ~
50 Hz
3500 W
13000 min
-1
25 m³/min
15 : 1
30 l
5,5 kg
II
IPX4
90,4 dB (A)
102,3 dB (A)
<2,5 m/s
2