Herunterladen Inhalt Inhalt Diese Seite drucken

Landxcape LX992 Installationsanleitung Seite 5

Vorschau ausblenden Andere Handbücher für LX992:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
Trees
Roots emerging from the ground should be avoided to prevent
damage.
Depressions and bumps
In case of large bumps (higher than 2cm) or dips (wider than
10cm and deeper than 2.5cm), please determine if the blades
TM
would touch the ground or if Landxcape
would get stuck. If
this is the case, either make the inclines smoother or exclude
Max.10cm
TM
these areas from Landxcape
's operation.
Max.2cm
Max.2.5cm
Slopes
TM
Your Landxcape
has the ability to safely climb slopes up
to 35% (20°)**/25% (15°)(Please refer to the Technical Data
& Declaration of Conformity for Max.slope ), so please avoid
areas steeper than this.
35% (20°) / 25%(15°)
**How to calculate the slope of your lawn:
The slope would be:
35cm (Elevation)
=35% (slope)
35cm
100cm (Length)
Max. 35% slope
100cm
Length
Placement of boundary wire on slopes
The upper boundary wire should NOT be placed on slopes
steeper than 35% (20°) / 25% (15°)(Please refer to the
Technical Data & Declaration of Conformity for Max.slope ), and
it should be placed at a distance of 26cm from any obstacle.
The lower boundary wire should NOT be placed on slopes
steeper than 17% (10°), and it should be placed at least 40cm
away from any obstacle when positioned on a slope that is
17%.
NOTE: The lower boundary wire cannot be laid across a slope
steeper than 17% as Landxcape
will slip and cross outside
TM
the wire, especially when the grass is wet.
EN