Verfügbare Sprachen

Recommended Temperature Values for Cooler
When to adjust
For cooling the fridge at minimum capacity
In normal usage
For cooling the fridge at maximum capacity

Temperature Settings Warnings

• It is not recommended that you operate your fridge in environments colder than 10°C in
terms of its efficiency.
• Do not start another adjustment before completing one adjustment.
• Temperature adjustments should be made according to the frequency of door openings
and the quantity of food kept inside the fridge.
• When you first switch on the appliance, allow it to operate for 24 hours in order to reach
normal operating temperature. During this time, do not open the door or place a lot of
food inside the appliance.
• If the appliance is switched off or unplugged, wait at least 5 minutes before plugging the
appliance in or restarting it in order to prevent damage to the compressor.
• Your fridge is designed to operate within specific ambient temperature ranges, according
to the climate class stated on the information label. We do not recommend operating
your fridge outside the stated temperatures value limits.
• Your appliance is designed to operate in the ambient temperature (T/SN = 10°C -
43°C) intervals stated in the standards, according to the climate class displayed on the
information label. We do not recommend operating your appliance out of the stated
temperature limits in terms of cooling effectiveness.
Climate class
T
ST
N
SN
The Turbo Fan (if available)
Do not block the air inlet and outlet openings when storing
food, otherwise air circulation provided by the turbo fan will
be impaired.
Meaning
Tropical
Subtropical
Temperate
Extended temperate
Inner Temperature (
C)
o
8
4
2
Ambient Temperature
This refrigerating appliance is intended to be used at
ambient temperatures ranging from 16 °C to 43 °C.
This refrigerating appliance is intended to be used at
ambient temperatures ranging from 16 °C to 38 °C.
This refrigerating appliance is intended to be used at
ambient temperatures ranging from 16 °C to 32 °C.
This refrigerating appliance is intended to be used at
ambient temperatures ranging from 10 °C to 32 °C.
EN -15-
Turbo fan

Werbung