Industrieprotokolle
16.4 PROFINET
Tab. 64:
Byte Content
0
Device status
1
Power supply unit
1
2
Power supply unit
2
3
Power supply unit
3
4
Power supply unit
4
5
Power supply unit
5
6
Power supply unit
6
7
Power supply unit
7
8
Power supply unit
8
9
Signal contact 1
10
Signal contact 2
11
Temperature
12
Fan
13
Module removal
14
ACA Removed
298
Gerätestatus
Access
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
ro
Value
Meaning
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
OK
2
Error
0
Unavailable
1
Closed
2
Open
0
Unavailable
1
Closed
2
Open
0
Unavailable
1
OK
2
Threshold value for temperature exceeded or not
reached
0
Unavailable
1
OK
2
Fan failure
0
Unavailable
1
OK
2
A module has been removed.
0
Unavailable
1
OK
2
The ACA has been removed.
UM Config OCTOPUS-8TX