FAULT: The faucet gets blocked
Possible cause
The juice has seeds or too much pulp.
FAULT: The machine stops every now and again
Possible cause
Insufficient ventilation.
Overload.
FAULT: Screen does not display information
Possible cause
Alteration to mains systems.
FAULT: The machine is in Self-Service mode and won't stop operating
Possible cause
Faucet not fitted or fitted incorrectly.
Faucet well fitted: possible internal fault.
Faucet block activated.
WARNING:
it from the mains. If, after making the checks stated here, the machine does not work,
call the technical service.
50
Any action to unblock the machine must be carried out by disconnecting
Correction
Disassemble and clean the faucet according Fig. 11A.
Correction
Check that the appliance's ventilation
grilles are not blocked.
Contact your technical service.
Correction
Turn off the machine and turn it back on again.
Correction
Fit the faucet in the manner indicated in Fig. 11A
Contact your technical service.
Put the block in horizontal position by
pressing the faucet downwards.