Installation
Installation spout and pump
• Place spout (7) on tap hole (ø 35 mm)
1
in sink
• Secure spout (7) with nut (8).
Ensure that seal and disc have been
inserted in between.
• Ensure that the spout which revolves
through 120° is centred with the bowl.
• Push pump (9) into the spout (7) from
2
underneath
• Push pump (9) upwards to the nut of
3
the screwed shank and insert retaining
ring (26). Ensure that retaining ring snaps
in correctly.
• Screw the galvanised steel ring (10) by
4
hand onto the end of the spout.
• Assemble spray (2) with non-return
5
valve (3) and seal (4) with spray hose (5)
by hand and push into the spout (7)
Installation control element
• Insert body (19) of control element into
6
tap hole (ø 35 mm) in sink
• Secure body (19) with nut (16).
Ensure that seal and disc have been
inserted in between.
• Ensure that control is adjusted to the
desired position on the sink
• Screw in hot water connection on left
and cold water connection on right of
body (19) and tighten securely by hand
• Push corrugated tube (14) over flexible
7
pipes (13)
• Screw spray hose (5) and body (19)
together tightly
• Push corrugated tube (14) over body (19)
and groove of lock nut
• Connect hot and cold water inlet hoses
8
to the angle valves. Ensure the seals sit
correctly.
Ensure that when the nuts are tightened,
the connection pipe is firmly held to
prevent it becoming twisted or detached
from the body of the tap.
• Secure corrugated tube (14) to base of
sink with cable tie (15)
• Secure weight (11) to spray hose.
Ensure position is correct.
Important information
• Do not kink the flexi-hoses
• Do not strain the flexi-hoses
• Only screw the flexi-hoses manually into the
body of the fitting.
• When connecting the flexi-hoses to the angle
valves, they must be held firmly to prevent the
hoses becoming twisted or detached from the
body of the fitting.
Maintanance
Jet regulator
1. Loosen jet regulator (1)
2. Flush jet regulator sieve under flowing water
3. Reinsert jet regulator
Replacing the cartridge
1. Shut off cold and hot water supply at the
angle valve
2. Unscrew lever (25) (anti-clockwise)
3. Loosen screw (23) and remove lever from
above
4. Unscrew the cartridge lock nut (21) and remove
cartridge (20)
5. Before inserting a new cartridge clean the
cartridge holder thoroughly.
6. Assemble in reverse order
Ensure that factory-set torque is maintained.
Care
In order that your BLANCO kitchen fitting will pro-
vide you with years of pleasure, we recommend
it is cleaned by wiping regularly with a soft cloth
(BLANCO microfibre cloth is recommended). Use
clean water or a mild cleaning agent.
On no account should abrasive (neither liquid nor
powder) cleaning agents or those containing alco-
hol or acid-based or other "aggressive" agents be
used. Scouring sponges are equally unsuitable.
The use of proscribed cleaning agents can dama-
ge the finish. Such damage is not covered by the
guarantee.
Guarantee
If a claim is made on the guarantee, the claimant
must produce the invoice on which the date of
purchase or installation is stated.