INSTAllATIoN
Now, remove the sticker covering the
sensor.
note: To prevent the sensor from enter-
10
ing into adjusting mode, do not step
within the sensor range for
5 seconds.
At this stage, to operate the flush
valve, step within the sensor range for
11
a minimum of 8 seconds.
move away to activate the flush valve.
A few seconds after your departure the
valve will flush the water.
note: Flushing will occur only when the
12
user steps within the sensor range for
a minimum of 8 seconds. To decrease
or increase the "delay in" time refer to
the section "Adjusting the sensor with
a remote control".
If needed adjust the flow capacity by
turning the regulating valve.
13
If the range is unsatisfactory, refer to the section entitled
"Settings adjustment".
22
SETTINGS ADJUSTmENT
8
SECONDS
adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold
the remote control straight in front of the sensor in a distance of about 6-8" (15-20cm).
Choose the function you want to adjust by pressing once on one of the function buttons.
After pressing once on a specific function button, a quick flashing of the LED at the
front of the sensor will occur. At this stage, you can change the setting by pressing the
(+) or the (-) buttons, every push will increase or decrease one level. After finishing the
adjustment, turn the water supply back on.
DETECTION
RANgE
DELAY IN TImE
FLOW TImE
DELAY OUT TImE
TEmPORARY OFF
FUNCTION
RESET