INSTAllATIoN
Shut off the water supply.
1
Connect the water supply pipe
to the water supply and slide the
wall flange on it.
Assemble the shut off valve to
2
the water supply pipe.
Assemble the valve body to the
shut off valve.
Slide the spud coupling nut over
the vacuum breaker pipe, do
3
not tighten the vacuum breaker
coupling nut yet.
20
INSTAllATIoN
Führen Sie das Vakuumbrecherrohr
4
in den Toiletten- oder Urinaleinlass
ein.
Connect the vacuum breaker pipe to
the flush valve body by tightening
the nut. make sure the friction ring is
placed between the flush valve body
and the vacuum breaker pipe.
5
Align the flush valve body on top of
the vacuum breaker pipe and se-
curely tighten the tailpiece coupling,
the vacuum breaker coupling and the
spud coupling respectively.
Connect the battery to the electronic
6
unit connector and place the battery
inside the flush valve cap.
Assemble the cap on the flush valve
body, making sure that the o-rings are
7
located in between and tighten the
screws.
Turn on the water supply and the shut
off valve and make sure that there is no
8
water leakage.
frICTIoN rING
INLET
CAP
CAP
SCrEw
o-rING
fLUSH VALVE