5. Technical Specifications
Input ACV
Input Voltage
Frequency
Idle Power Consumption
Full Load Power
Consumption
Output DCV
Output Voltage
Output Current
Power
Total Output Power
Average Efficiency
Low Load Efficiency (10%)
General
Energy efficiency class
Protection
Operating Environment
Storage Environment
Mean Operation Time (MTBF)
Plug Type
Cable Length
Dimensions
Weight
100 ... 240 V AC
50 / 60 Hz
< 0.1 W
ca. 0.4 A
3.0V / 4.5V /5.0V / 6.0V/ 7.5V/ 9.0V /12.0V
1500 mA
3.0V (4.5W)
/ 4.5V (6.75W) /
5.0V (7.5W)
/ 6.0V (9W)
7.5V (11.25W) / 9.0V (13.5W) /
12.0V (18W) MAX
>72.8% (for 3.0V); >75.9% (for 4.5V);
>76.6% (for 5.0V); >81.3% (for 6.0V);
>82.6% (for 7.5V); >83.5% (for 9.0V);
>85.0% (for 12.0V)
>62.8% (for 3.0V); >65.9% (for 4.5V);
>66.6% (for 5.0V); >71.3% (for 6.0V);
>72.6% (for 7.5V); >73.5% (for 9.0V);
>75.0% (for 12.0V)
Level VI
Class II
0 ... 25°C / 20 ... 85% R.H.
-20 ... 60°C / 10 ... 90% R.H.
> 30.000 Hours
Euro 2-poles, C/F
ca. 180cm
82 mm x 51.6 mm x 35.9 mm
130 g
11
/