Technische Daten . Technical Data Spannungsversorgung Power supply Supply voltage U B = 4.75 V to 30 V Integrated reverse polarity protection Typical current consumption without encoder: 160 mA with 5 V 85 mA with 10 V 40 mA with 30 V Encoder-Interface (X1) Encoder interface (X1) EnDat interface 2.1 or 2.2...
Seite 13
Switch Code output = Gray Code output: Gray Excess Normal counting direction Inverse counting direction Enabling signals A\ and B\ without function A\ = Enabling signal for bit 3 to bit 14 B\ = Enabling signal for bit 1 and bit 2 Enabling signals A\ and B\ without function A\ = Enabling signal for bit (7 )8 to bit 14...
Seite 14
Elektrischer Anschluss . Electrical Connection Eingangssignale EnDat X1/ Input signals EnDat X1 EPC 100 1ZB17 27S21 ID 685162-01 EPC 100 1ZB17 27S12 ID 685162-02 Signal 0 V (internal shield)
Ausgangssignale X2/ Output signals X2 EPC 100 1ZB17 27S21 ID 685162-01 Signal Signal 0 V (U N ) Enable A\ Enable B\ Not connected or B10 (depending on S9) Not connected or B9 (depending on S10) Bit 8 Bit 7...
Seite 16
Elektrischer Anschluss . Electrical Connection Ausgangssignale X2/ Output signals X2 EPC 100 1ZB17 27S12 ID 685162-02 Signal Signal 0 V (U N ) Not connected or B9 (depending on S10) Bit 8 Bit 7 Bit 6 Bit 5 Bit 4...
Seite 20
DR. JOHANNES HEIDENHAIN GmbH Dr.-Johannes-Heidenhain-Straße 5 83301 Traunreut, Germany { +49 8669 31-0 | +49 8669 32-5061 E-mail: info@heidenhain.de Technical support | +49 8669 32-1000 Measuring systems { +49 8669 31-3104 E-mail: service.ms-support@heidenhain.de NC support { +49 8669 31-3101 E-mail: service.nc-support@heidenhain.de...