Safety and Installation Instructions for AC Modules   
IMPORTANT SAFETY INSTRUCTIONS 
SAVE THESE INSTRUCTIONS  
 
1.0 Introduction   
This  document  provides  safety  and  installation  instructions  for  the 
SunPower AC photovoltaic (PV) modules described herein, all of which 
bear both TUV and EnTest logos on the product label in respect to DC 
and AC (Microinverter) standards: 
Important! Please read these instructions in their entirety before 
installing, wiring, or using this product in any way. Failure to comply 
with these instructions will invalidate the Maxeon Solar 
Technologies Limited Warranty for PV Modules and/or Enphase 
Energy Limited Warranty for microinverters. 
 
1.1 Definition of Terms 
AC Module: Maxeon 5 and Perfomance 3 AC module 
DC  Module:  A  typical  photovoltaic  solar  module  without  microinverter  unit 
attached. 
Enphase  Microinverter:   Smart  grid  ready  IQ  7A  microinverter  converts  the  DC 
output of the PV module into grid‐compliant AC power. 
Enphase AC cable: also called Q Cable, it is an AC cable with a length varying from 
1.3m to 2.3m depending to AC Module orientation (Portrait or Landscape), with 
3.3  mm2  cross  section,  double  insulated,  outdoor  rated  with  integrated 
connectors for microinverters. Maxeon Solar Technologies recommends the use 
at least of 2.0m long Q cable for greater flexibility in module installation in Portrait 
configuration.  AC  Module  plugs  directly  into  the  Q  that  includes  factory 
integrated connectors. 
Enphase Enlighten: Web‐based monitoring and management software. Installers 
can use Enlighten Manager to view detailed performance data, manage multiple 
PV systems, etc. 
DC  Connector:  Maxeon  Solar  Technologies  recommends  using  the  same  brand 
connector  in  a  given  PV  system.  Approved  compatible  connectors:  Tyco 
Electronics PV4S  
 
1.2 Disclaimer of Liability 
The installation techniques, handling and use of this product are beyond company 
control. Therefore, Maxeon Solar Technologies does not assume responsibility for 
loss, damage, or expense resulting from improper installation, handling, or use.  
 
1.3 Certified Body Certification Information 
This product intents to meet or exceed the requirements set forth by IEC 62109‐
3  for  SunPower  AC  modules.  The  IEC  62109‐3  Standard  covers  flat‐plate  PV 
modules  intended  for  installation  on  buildings;  or  those  intended  to  be 
freestanding. The TUV certification does not include integration into a building 
surface because additional requirements may apply. This product is not intended 
for  use  where  artificially  concentrated  sunlight  is  applied  to  the  module.  This 
manual shall be used in combination with industry recognized best practices and 
SunPower AC modules should be installed by certified professionals only.   
 
1.4 Limited Warranty 
AC Module limited warranties are described in the Maxeon Solar Technologies 
warranty  certificates  obtainable  at 
limited warranty document). 
                                  ©2021 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice.     
www.sunpower.maxeon.com 
(Refer  to  the 
2.0 Safety Precautions 
Before installing this device, read all safety instructions in this document. 
 
Danger! AC Modules generate internal direct current (DC) and output 
alternating current (AC); and are a source of voltage when under load and 
when exposed to light. Electrical currents can arc across gaps and may 
cause injury or death if improper connection or disconnection is made; or if 
contact is made with module leads that are frayed or torn.  
 
 Disconnect the AC source from all AC Modules and/or  cover all modules in 
the  PV  array  with  an  opaque  cloth  or  material  before  making  or  breaking 
electrical connections 
 Do not connect or disconnect modules when current from the modules in the 
string or an external source is present 
 Use  only  the  AC  locking  connectors  in  order  to  defend  against  untrained 
personnel disconnecting the modules after they have been installed. 
 All installations must be performed  in compliance with the applicable local 
codes.  
 Installation  should  be  performed  only  by  qualified  and  suitably  licensed 
personnel 
 Remove  all  metallic  jewelry  prior  to  installing  this  product  to  reduce  the 
chance of accidental exposure to live circuits.  
 Use only insulated tools to reduce your risk of electric shock. 
 Do not stand on, drop, scratch, or allow objects to fall on AC Modules. 
 
 Broken  glass,  J‐boxes,  broken  connectors,  and/or  damaged  backsheets  are 
electrical hazards as well as laceration hazards. If a module is cracked after 
installation, a qualified person should remove the module from the array and 
contact the supplier for disposal instructions.  
 Do not install or handle modules when they are wet or during periods of high 
wind.    
 Unconnected connectors must always be protected from pollution (e.g. dust, 
humidity,  foreign  particles,  etc.),  prior  to  installation.  Do  not  leave 
unconnected (unprotected) connectors exposed to the environment. A clean 
installation  environment  is  essential  in  order  to  avoid  performance 
degradation. 
 Do not block drain holes or allow water to pool in or near AC Module frames 
 Contact your module supplier if maintenance is necessary. 
 Save these instructions!    
3.0 Electrical Characteristics 
Electrical characteristics and grid interaction data are shown in Table 2 and AC 
Module datasheet. It is the installer's responsibility to set the grid profile and to 
check  Enphase  pre‐configured  country  grid  detail  and  this  can  be  done  with 
internet access and by connecting into the Enphase Enlighten system.  
 
If an installation involves a SunPower AC module which does not appear on this 
list,  please  consult  the  product  label  on  the  back  of  the  module  or  visit 
www.sunpower.maxeon.com for the product datasheet.  
 
As a reminder for DC modules:  a photovoltaic module may produce more current 
and/or  voltage  than  reported  at  STC.  Sunny,  cool  weather  and  reflection  from 
snow or water can increase current and power output. Therefore, the values of 
Isc and Voc marked on the module should be multiplied by a factor of 1.25 when 
determining  component  voltage  ratings,  conductor  ampacities,  fuse  sizes,  and 
size  of  controls  connected  to  PV  output.  An  additional  1.25  multiplier  may  be 
required  by  certain  local  codes  for  sizing  fuses  and  conductors.  SunPower 
recommends the use of open‐ circuit voltage temperature coefficients listed on 
the datasheets when determining Maximum System Voltage. 
 
3.1 Fire Rating 
The AC Module has the same fire rating as DC modules.    
4.0 Electrical Connections  
Modules  must  only  be  connected  using  the  correct  Enphase  AC  cable  and 
integrated connectors. Do not alter any connectors.   
 