Intercom Server S6
Cost-efficient, compact and high performance Intercom Server for rack mounting, with VirtuoSIS on
board.
Rack installation with the rack mount kit included in extent of supply
Release the rails
a
a
b
Install the rail system
b
c
d
The earthquake
e
security screw has
to be tightened with
max. 1 Nm.
1.
To release the locking
mechanism, press the rear
side of the toothed levers
together
and pull the hook
simultaneously as far as it will
go
.
If the rail is difficult to access, use
the provided unlocking tool to
release it:
1.
Put the unlocking tool into the
holes of the toothed levers
2.
Press the toothed levers
together (see illustration
to the left) and simultaneously
pull the hook as far as it will
go.
1.
Identify the right and the left
rail (see label on the rail).
2.
Position the left rail on the
rear left support upright (or on
a
the support bracket) by inser-
ting the retaining bolts
3.
Position the left rail on the
front left support upright
so that the support upright
resides between the two
brackets of the rail.
4.
Press the left rail together
5.
Move the left rail outwards
until the designated position
(grid of support upright)
is reached
. The black
bolts must lock into the
corresponding holes.
6.
Press the bracket backwards
The toothed levers
until the rail engages
must be closed.
7.
Check if the rail is fixed
The two black bolts
by pressing the left rail
must be flush with
backwards.
the bracket.
8.
(Optional) Fix each rail with
one earthquake security screw
M5
.
9.
Repeat this procedure to
install the right rail.
Lift S6 into position
Complete installation
.
.
.
1.
Fully extend the telescopic
rails until they lock in place
. The telescopic rails must
click into place so that they
can no longer be moved.
2.
At a slight angle, lower the S6
onto the rear mounting point
on the telescopic rails
.
3.
Fold down the S6
while
pressing the rails inwards
to the S6. Make sure that
all rack mounting bolts (6
or 8) are properly seated in
the mounting points on the
telescopic rails and that the
locking bars engage
. If it is
not properly seated, try again
starting with
.
1.
Release the locking
mechanism of both rails
.
2.
Push the S6 as far as it will go
into the rack
until the QRLs
(quick release levers) engage
.
Make sure that the QRLs are engaged
properly on both sides.
Be careful with your fingers. You can
pinch them if the QRL changes to the
release position.

Werbung

loading

Inhaltszusammenfassung für Commend S6

  • Seite 1 Complete installation Install the rail system Release the locking mechanism of both rails Push the S6 as far as it will go into the rack until the QRLs Identify the right and the left (quick release levers) engage rail (see label on the rail).
  • Seite 2 Extent of supply Power cable standards: • Server For the S6, the power cable with country-specific • Electromagnetic compatibility (directive 2014/30/EU) • Rack mounting kit (incl. 2 earthquake security plug is available separately: • The restriction of the use of certain hazardous substances in electrical and electronic screws and 4 centring screws for the support •...
  • Seite 3 Rackmontage mit dem im Lieferumfang enthaltenen Rackmontage-Kit Die Teleskopschienen müssen einrasten und dürfen sich Schienen entriegeln nicht mehr bewegen lassen. Setzen Sie den S6 in einem Drücken Sie das hintere Ende leichten Winkel am hinteren der Zahnhebel zusammen, um Montagepunkt der Teleskop- die Verrieglung zu lösen...
  • Seite 4 Dieses Gerät entspricht durch die Erfüllung entsprechender Standards folgenden Lieferumfang Netzkabel europäischen Richtlinien: • Server Für den S6 ist das Kaltgerätekabel mit länderspezi- • Elektromagnetische Verträglichkeit (Richtlinie 2014/30/EU) • Rackmontage-Kit (inkl. 2 Erdbeben- fischem Stecker separat erhältlich: • Beschränkung der Verwendung bestimmter gefährlicher Stoffe in Elektro- und sicherungs schrauben und 4 Zentrierschrau- •...