Guidance and manufacture's declaration – electromagnetic emission
The device is intended for use in the electromagnetic environment specified below. The customer of the
user of the device should assure that it is used in such an environment.
Electromagnetic environment – guidance
Emission test
Compliance
The device use RF energy only for its internal function.
RF emissions
Therefore, its RF emissions are very low and are not likely to
Group 1
CISPR 11
cause any interference in nearby electronic equipment.
RF emission
Class B
CISPR 11
The device is suitable for use in all establishments, including
domestic establishments other than domestic and those directly
Harmonic emissions
Not applicable
connected to the public low-voltage power supply network that
IEC 61000-3-2
supplies buildings used for domestic purposes.
Voltage fluctuations/
Not applicable
flicker emissions
IEC 61000-3-3
Recommended separation distances between
portable and mobile RF communications equipment and the device
The device is intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of the device can help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment
(transmitters) and the device as recommended below, according to the maximum output power of the
communications equipment.
Separation distance according to frequency of transmitter (m)
Rated maximum output
power of transmitter
(W)
150 KHz to 80 MHz
For transmitters rated at a maximum output power not listed above, the recommended separation
distance d in metres (m) can be estimated using the equation applicable to the frequency of the
transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the
transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
137
80 MHz to 800 MHz
800 MHz to 2.7 GHz
Guidance and manufacturer's declaration - electromagnetic immunity
The device is intended for use in the electromagnetic environment specified below. The customer or the
user of the device, should assure that it is used in such an environment.
Test
a)
Band
frequency
Service
a)
Modulation
(MHz)
(MHz)
385
380-390
TETRA 400
Pulse Modulation
18 Hz
FM
c)
450
430-470
GMRS 460,
±5 kHz deviation
FRS 460
1 kHz sine
Pulse
710
Modulation
704-787
LTE Band 13,
745
217 Hz
17
780
GSM 800/900,
Pulse
810
TETRA 800,
Modulation
800-960
870
iDEN 820,
18 Hz
CDMA 850,
930
LTE Band 5
GSM 1800;
Pulse
1720
CDMA 1900;
Modulation
GSM 1900;
217 Hz
1700-1990
1845
DECT;
1970
LTE Band 1,3
4,25;UMTS
Bluetooth,
Pulse
2450
2400-2570
WLAN
Modulation
802.11 b/g/n,
217 Hz
RFID 2450,
LTE Band 7
5240
WLAN 802.11
Pulse
a/n
Modulation
5500
5100-5800
217 Hz
5785
NOTE If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting
antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is
permitted by IEC 61000-4-3.
a ) For some services, only the uplink frequencies are included.
b ) The carrier shall be modulated using a 50% duty cycle square wave signal.
c ) As an alternative to FM modulation. 50% pulse modulation at 18 Hz may be used because while it
does not represent actual modulation, it would be worst case.
The MANUFACTURER should consider reducing the minimum separation distance, based on RISK
MANAGEMENT, and using higher IMMUNITY TEST LEVELS that are appropriate for the reduced
minimum separation distance. Minimum separation distances for higher IMMUNITY TEST LEVELS
shall be
calculated using the following equation:
Where P is the maximum power in W, d is the minimum separation distance in m, and E is the
IMMUNITY
TEST LEVEL in V/m.
Maximum
IMMUNITY
Distance
a)
power
TEST LEVEL
(m)
(w)
(V/m)
b)
1.8
0.3
27
2
0.3
28
b)
0.2
0.3
9
b)
2
0.3
28
b)
2
0.3
28
b)
2
0.3
28
b)
0.2
0.3
9
138